Busadee Pratumvinit1, Kanit Reesukumal2, Sithikan Hanyongyuth2, Sujitra Wangchaijaroenkit2, Julaporn Pooliam3, Gerald J Kost4, Panumas Kamkang2, Tze Ping Loh5.
Abstract
Hb mutations can alter the structure, behavior, stability, or quantity of the globin chain produced. Some Hb variants shorten the erythrocyte life span, resulting in physiologically lower hemoglobin A1c (HbA1c) levels. The hemoglobin E (HbE) phenotype involves a single-nucleotide polymorphism that reduces β-globin chain synthesis. We compared the HbA1c levels of subjects with normal Hb (HbAA; N=131) and HbE (N=148) phenotypes, examining potential hematological and biochemical factors contributing to differences in HbA1c levels. All had normal fasting plasma glucose (<5.6 mmol/L), AST, ALT, and creatinine levels. Mean±SD HbA1c levels differed between HbAA and HbE subjects: 5.5±0.3% and 5.3±0.3% (P<0.001) according to an immunoassay, and 5.5±0.3% and 5.3±0.3% (P<0.001) according to cation-exchange HPLC, respectively. In multiple logistic regression, only mean corpuscular volume (P<0.001) contributed to the difference in HbA1c levels between groups. Although a 0.2% difference in HbA1c is relatively small and unlikely to alter clinical decisions, epidemiologically, this can lead to misclassification of a significant proportion of the population, especially since the threshold of non-diabetes HbA1c (≤5.6%) falls very close to the HbA1c median of the general population. © The Korean Society for Laboratory Medicine.Entities:
Keywords: HPLC; Hemoglobin A1c; Hemoglobin E; Immunoassay
Mesh:
Substances:
Year: 2019 PMID: 30430785 PMCID: PMC6240528 DOI: 10.3343/alm.2019.39.2.209
Source DB: PubMed Journal: Ann Lab Med ISSN: 2234-3806 Impact factor: 3.464
Factors associated with differences in HbA1c levels between HbAA (N=131) and HbE (N=148) subjects
| Factors | HbAA (mean±SD) | HbE (mean±SD) | Univariate analysis | Multivariate analysis | ||
|---|---|---|---|---|---|---|
| Crude OR (95% CI) | Adjusted OR (95% CI) | |||||
| FPG (mmol/L) | 4.90 ± 0.30 | 4.80 ± 0.40 | 0.67 (0.33–1.35) | 0.260 | - | - |
| Total cholesterol (mmol/L) | 5.40 ± 0.90 | 5.20 ± 0.80 | 0.80 (0.61–1.05) | 0.100 | 0.60 (0.29–1.24) | 0.17 |
| Triglycerides (mmol/L) | 1.10 ± 0.60 | 1.10 ± 0.60 | 0.91 (0.61–1.36) | 0.660 | - | - |
| HDL-cholesterol (mmol/L) | 1.70 ± 0.40 | 1.70 ± 0.40 | 1.04 (0.61–1.76) | 0.890 | - | - |
| LDL-cholesterol (mmol/L) | 3.20 ± 0.90 | 3.10 ± 0.80 | 0.78 (0.58–1.04) | 0.090 | - | - |
| Creatinine (μmol/L) | 67.20 ± 11.80 | 66.70 ± 12.10 | 1.00 (0.98–1.02) | 0.710 | - | - |
| AST (μkat/L) | 0.32 ± 0.07 | 0.30 ± 0.07 | 0.01 (0.00–0.41) | 0.010 | - | - |
| ALT (μkat/L) | 0.28 ± 0.12 | 0.25 ± 0.11 | 0.11 (0.01–0.87) | 0.040 | 0.00 (0.00–5.57) | 0.14 |
| Hemoglobin (g/L) | 132.80 ± 10.60 | 125.50 ± 10.20 | 0.93 (0.91–0.96) | < 0.001 | 0.99 (0.93–1.06) | 0.83 |
| Hematocrit (L/L) | 0.41 ± 0.03 | 0.39 ± 0.03 | 0.2 × 10-8 (0.7 × 10-12-0.9 × 10-5) | < 0.001 | - | - |
| MCV (fL) | 88.00 ± 4.40 | 76.90 ± 3.10 | 0.27 (0.17–0.42) | < 0.001 | 0.25 (0.16–0.41) | < 0.001 |
| MCH (fmol/cell) | 1.77 ± 0.10 | 1.53 ± 0.08 | 0.2 × 10-17 (0.2 × 10-22-0.2 × 10-12) | < 0.001 | - | - |
| MCHC (mmol/L) | 20.10 ± 0.50 | 19.90 ± 0.40 | 0.44 (0.25–0.75) | 0.003 | - | - |
Abbreviations: HbAA, normal hemoglobin; HbA1c, hemoglobin A1c; HbE, hemoglobin E; OR, odds ratio; CI, confidence interval; FPG, fasting plasma glucose; MCV, mean corpuscular volume; MCH, mean corpuscular Hb; MCHC, mean corpuscular Hb concentration.
Fig. 1Histogram of HbA1c results in the study population. (A) and (B) show HbA1c levels measured by the Roche Integra 800CTS immunoassay (Roche Diagnostics, Mannheim, Germany). (C) and (D) show HbA1c levels measured by Bio-Rad D10 HPLC (Bio-Rad Laboratories, Hercules, CA, USA).
Fig. 2Bland-Altman plots of HbA1c results for HbAA and HbE subjects. (A) and (B) show the absolute differences in HbA1c results between the immunoassay (Roche Integra 800CTS; Roche Diagnostics, Mannheim, Germany) and cation-exchange HPLC (Bio-Rad D-10; Bio-Rad Laboratories, Hercules, CA, USA). (C) and (D) show percentage of the mean differences in HbA1c results. Left panels are for HbAA subjects (N=131) and right panels are for HbE subjects (N=148). The bold solid lines denote mean bias and 95% confidence intervals. The dashed lines denote the 95% limits of agreement of the difference, and the dotted lines denote the College of American Pathologists allowable total error (TEa, ±6%) [17].