OBJECTIVES: To evaluate prospectively the clinical and radiographic outcomes after ten years of short (6 mm) implants with a moderately rough surface supporting single crowns in the posterior region. MATERIAL AND METHODS: Forty 6 mm modified sandblasted large-grit acid-etched (mod-SLA), soft tissue level implants were installed in the distal segments of 35 consecutive patients. After 6 weeks of healing, abutments were tightened, and single porcelain-fused-to-metal crowns were cemented. Implant survival, marginal bone loss, and clinical crown/implant ratio were evaluated at various time intervals up to 10 years after loading. RESULTS: Two out of the 40 implants were lost before loading, one implant was lost after 7 years because of peri-implantitis. One patient with two implants died and was excluded from analysis. Two patients did not come at the 10-year follow-up and were considered as drop out (2 implants). The survival rate was 91.7% (n = 36). Thirty-three implants were available for marginal bone loss evaluation. A mean marginal bone loss after 10 years of function was 0.8 ± 0.7 mm. Between 5 and 10 years, the loss was 0.2 ± 0.4 mm. No technical complications were registered during the 10-year period. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2.0 after 10 years of loading with no increase between 5 and 10 years. CONCLUSION: Short (6 mm) implants with a moderately rough surface supporting single crowns in the posterior region and loaded after 6-7 weeks maintained full function for at least 10 years with low marginal bone resorption.
OBJECTIVES: To evaluate prospectively the clinical and radiographic outcomes after ten years of short (6 mm) implants with a moderately rough surface supporting single crowns in the posterior region. MATERIAL AND METHODS: Forty 6 mm modified sandblasted large-grit acid-etched (mod-SLA), soft tissue level implants were installed in the distal segments of 35 consecutive patients. After 6 weeks of healing, abutments were tightened, and single porcelain-fused-to-metal crowns were cemented. Implant survival, marginal bone loss, and clinical crown/implant ratio were evaluated at various time intervals up to 10 years after loading. RESULTS: Two out of the 40 implants were lost before loading, one implant was lost after 7 years because of peri-implantitis. One patient with two implants died and was excluded from analysis. Two patients did not come at the 10-year follow-up and were considered as drop out (2 implants). The survival rate was 91.7% (n = 36). Thirty-three implants were available for marginal bone loss evaluation. A mean marginal bone loss after 10 years of function was 0.8 ± 0.7 mm. Between 5 and 10 years, the loss was 0.2 ± 0.4 mm. No technical complications were registered during the 10-year period. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2.0 after 10 years of loading with no increase between 5 and 10 years. CONCLUSION: Short (6 mm) implants with a moderately rough surface supporting single crowns in the posterior region and loaded after 6-7 weeks maintained full function for at least 10 years with low marginal bone resorption.
Authors: Alessandro Cucchi; Alessandro Bianchi; Paolo Calamai; Lisa Rinaldi; Francesco Mangano; Elisabetta Vignudelli; Giuseppe Corinaldesi Journal: BMC Oral Health Date: 2020-08-05 Impact factor: 2.757
Authors: Fabio Rossi; Lorenzo Tuci; Lorenzo Ferraioli; Emanuele Ricci; Andreea Suerica; Daniele Botticelli; Gerardo Pellegrino; Pietro Felice Journal: Int J Environ Res Public Health Date: 2021-04-06 Impact factor: 3.390
Authors: Bianca Di Murro; Nicola Pranno; Andrea Raco; Roberto Pistilli; Giorgio Pompa; Piero Papi Journal: Int J Environ Res Public Health Date: 2020-11-12 Impact factor: 3.390
Authors: Andreas Stavropoulos; Rebecca Sandgren; Benjamin Bellon; Anton Sculean; Benjamin E Pippenger Journal: Materials (Basel) Date: 2021-03-29 Impact factor: 3.623