| Literature DB >> 30424309 |
Jun Kim1, Dongin Hong2, Mohsin Ali Badshah3, Xun Lu4, Young Kyu Kim5, Seok-Min Kim6,7.
Abstract
The application of microtechnology to traditional mechanical industries is limited owing to the lack of suitable micropatterning technology for durable materials including metal. In this research, a glassy carbon (GC) micromold was applied for the direct metal forming (DMF) of a microstructure on an aluminum (Al) substrate. The GC mold with microdome cavities was prepared by carbonization of a furan precursor, which was replicated from the thermal reflow photoresist master pattern. A microdome array with a diameter of 8.4 μm, a height of ~0.74 μm, and a pitch of 9.9 μm was successfully fabricated on an Al substrate by using DMF at a forming temperature of 645 °C and an applied pressure of 2 MPa. As a practical application of the proposed DMF process, the enhanced boiling heat transfer characteristics of the DMF microdome Al substrate were analyzed. The DMF microdome Al substrate showed 20.4 ± 2.6% higher critical heat flux and 34.1 ± 5.3% higher heat transfer coefficient than those of a bare Al substrate.Entities:
Keywords: direct metal forming; enhanced boiling heat transfer; glassy carbon micromold; metallic microstructure
Year: 2018 PMID: 30424309 PMCID: PMC6187845 DOI: 10.3390/mi9080376
Source DB: PubMed Journal: Micromachines (Basel) ISSN: 2072-666X Impact factor: 2.891
Figure 1Schematic of a fabrication process for the glassy carbon (GC) mold and the direct metal forming (DMF) process.
Figure 2Scanning electron microscope (SEM) images of (a) microdome cavities on GC mold and (b) microdome array on aluminum (Al) substrate fabricated by DMF with a temperature of 645 °C and a pressure of 2 MPa.
Figure 3(a–c) Photographs of constructed DMF system; (a) whole system; (b) graphite pressing jig unit with Al substrate, GC mold, and cover graphite plate; and (c) vacuum chamber with infrared heater during the heating stage; (d) pressure and temperature histories in DMF process.
Figure 4Three-dimensional surface profiles of (a) a GC mold and (b) a DMF microdome Al substrate obtained by laser confocal microscope.
Figure 5Schematic of experimental setup for boiling heat transfer using fabricated sample.
Uncertainty sources and error values.
| Uncertainty Source | Error |
|---|---|
| Machining error for measuring position | ±0.01 mm |
| J-type thermocouple reading | ±0.15 K |
| Thermal conductivity of Cu | ±2% |
| Thermal conductivity of Al | ±2.1% |
| Thermal contact resistance | ±2.37% |
| Surface temperature reading | ±0.62% |
| Heat flux | ±8.72% |
| Heat transfer coefficient | ±8.74% |
Figure 6Comparison of the boiling curves of three DMF microdome Al substrates and a bare Al substrate.