Literature DB >> 3042282

Donor failure after corneal transplantation surgery.

J N Buxton1, J A Seedor, H D Perry, R C Eagle, J A Pecego.   

Abstract

Donor failure refers to graft edema present within the first 24 h after penetrating keratoplasty that persists in spite of maximal medical therapy. We reviewed the case histories of 1,351 penetrating keratoplasties. Of these, 17 (1.2%) were considered donor failures. Five cases were histopathologically consistent with Fuchs' dystrophy. Seven cases demonstrated mechanical stripping of the endothelium. Five cases, all from the same eye bank, revealed an absence of posterior stromal keratocytes. Storage medium at the eye bank of origin was found to have an alkaline pH. Careful preoperative evaluation of donor corneas is emphasized, but if an apparent "epidemic" of donor failure occurs, a thorough investigation of the eye bank methodology should be initiated.

Entities:  

Mesh:

Year:  1988        PMID: 3042282

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  7 in total

1.  Corneal graft reversal: Histopathologic report of two cases.

Authors:  Abdullah A Qahtani; Hind M Alkatan
Journal:  Saudi J Ophthalmol       Date:  2014-04-24

2.  Graft failure in human donor corneas due to transmission of herpes simplex virus.

Authors:  S Biswas; P Suresh; R E Bonshek; G Corbitt; A B Tullo; A E Ridgway
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

3.  Guttae in the donor after Descemet-stripping automated endothelial keratoplasty.

Authors:  Bryan S Lee; Ajoy S Virdi; Kristin M Hammersmith; Albert S Jun
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-05-12       Impact factor: 3.117

Review 4.  Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

Authors:  Emily C Greenlee; Young H Kwon
Journal:  Int Ophthalmol       Date:  2008-06       Impact factor: 2.031

5.  Detection of herpes simplex virus DNA in donor cornea culture medium by polymerase chain reaction.

Authors:  D J Morris; G M Cleator; P E Klapper; R J Cooper; E O Biney; C Dennett; B Marcyniuk; A B Tullo
Journal:  Br J Ophthalmol       Date:  1996-07       Impact factor: 4.638

6.  Donor and surgical risk factors for primary graft failure following Descemet's stripping automated endothelial keratoplasty in Asian eyes.

Authors:  Marcus Ang; Hla M Htoon; Howard Y Cajucom-Uy; Donald Tan; Jodhbir S Mehta
Journal:  Clin Ophthalmol       Date:  2011-10-18

7.  Elevation of preoperative recipient aqueous cytokine levels in eyes with primary graft failure after corneal transplantation.

Authors:  Takefumi Yamaguchi; Kazunari Higa; Kazuo Tsubota; Jun Shimazaki
Journal:  Mol Vis       Date:  2018-09-13       Impact factor: 2.367

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.