C Horn1, C Négrier2, U Kalina1, W Seifert1, K D Friedman3. 1. CSL Behring, Marburg, Germany. 2. Hôpital Louis Pradel, University Claude Bernard Lyon 1, Lyon, France. 3. Blood Research Institute, Blood Center of Wisconsin, Milwaukee, WI, USA.
Abstract
Essentials Performance of the one-stage clotting (OSC) assay varies with the clotting activator used. Recombinant FIX-albumin fusion protein (rIX-FP) was reliably monitored with most OSC reagents. rIX-FP shows comparable reagent-dependent variability to other rFIX products in the OSC assay. Actin® FS and kaolin-based reagents underestimated rIX-FP activity by around 50% in the OSC assay. SUMMARY: Background Measuring factor IX activity (FIX:C) with one-stage clotting (OSC) assays, based on the activated partial thromboplastin time (APTT), is the current mainstay of diagnostic techniques for hemophilia B. Assessing the performance of new recombinant FIX (rFIX) products in OSC assays is essential, as APTT reagents from different manufacturers yield different potency estimates for rFIX. Objectives To evaluate the extent to which choice of reagent composition influences rFIX potency measurements of recombinant FIX-albumin fusion protein (rIX-FP, IDELVION) activity in OSC assays. Methods rIX-FP was added to FIX-deficient plasma, and FIX:C was assessed centrally and locally in a multicenter international field study with a variety of commercial OSC APTT reagents. Paired sample analysis of clinical samples was performed to compare values of FIX:C from local and central laboratories. In-house bioanalytical investigations with spiked samples were conducted to compare the APTT-reagent dependent variability of rIX-FP with unmodified rFIX and rFIX Fc fusion protein (rFIXFc). Results Central and local assessments of FIX:C from 10 countries and 21 participating centers showed comparable results to those from the central laboratory across the majority of 18 different APTT reagents from both clinical and spiked samples. There was a consistent underestimation of rIX-FP activity of ≈ 50% with OSC assays using Actin FS or kaolin-based APTT reagents. In the bioanalytical study, rIX-FP showed comparable variability in OSC assays to unmodified rFIX and rFIXFc. Conclusions rIX-FP activity can be accurately measured by the use of OSC assays with the majority of commercial reagents. Actin FS or kaolin-based reagents will probably lead to a 50% underestimation of activity.
Essentials Performance of the one-stage clotting (OSC) assay varies with the clotting activator used. Recombinant FIX-albumin fusion protein (rIX-FP) was reliably monitored with most OSC reagents. rIX-FP shows comparable reagent-dependent variability to other rFIX products in the OSC assay. Actin® FS and kaolin-based reagents underestimated rIX-FP activity by around 50% in the OSC assay. SUMMARY: Background Measuring factor IX activity (FIX:C) with one-stage clotting (OSC) assays, based on the activated partial thromboplastin time (APTT), is the current mainstay of diagnostic techniques for hemophilia B. Assessing the performance of new recombinant FIX (rFIX) products in OSC assays is essential, as APTT reagents from different manufacturers yield different potency estimates for rFIX. Objectives To evaluate the extent to which choice of reagent composition influences rFIX potency measurements of recombinant FIX-albumin fusion protein (rIX-FP, IDELVION) activity in OSC assays. Methods rIX-FP was added to FIX-deficient plasma, and FIX:C was assessed centrally and locally in a multicenter international field study with a variety of commercial OSC APTT reagents. Paired sample analysis of clinical samples was performed to compare values of FIX:C from local and central laboratories. In-house bioanalytical investigations with spiked samples were conducted to compare the APTT-reagent dependent variability of rIX-FP with unmodified rFIX and rFIX Fc fusion protein (rFIXFc). Results Central and local assessments of FIX:C from 10 countries and 21 participating centers showed comparable results to those from the central laboratory across the majority of 18 different APTT reagents from both clinical and spiked samples. There was a consistent underestimation of rIX-FP activity of ≈ 50% with OSC assays using Actin FS or kaolin-based APTT reagents. In the bioanalytical study, rIX-FP showed comparable variability in OSC assays to unmodified rFIX and rFIXFc. Conclusions rIX-FP activity can be accurately measured by the use of OSC assays with the majority of commercial reagents. Actin FS or kaolin-based reagents will probably lead to a 50% underestimation of activity.
Authors: Steffen Rosen; Stefan Tiefenbacher; Mary Robinson; Mei Huang; Jaydeep Srimani; Donnie Mackenzie; Terri Christianson; K John Pasi; Savita Rangarajan; Emily Symington; Adam Giermasz; Glenn F Pierce; Benjamin Kim; Stephen J Zoog; Christian Vettermann Journal: Blood Date: 2020-11-26 Impact factor: 22.113
Authors: Angelique Nederlof; Steve Kitchen; Piet Meijer; Marjon Cnossen; Nae Ali Pour; Geoffrey Kershaw; Ian Jennings; Isobel Walker; Moniek P M de Maat Journal: J Thromb Haemost Date: 2020-06-10 Impact factor: 5.824