Literature DB >> 30418068

Excellent results of large-diameter ceramic-on-ceramic bearings in total hip arthroplasty: Is Squeaking Related to Head Size.

W G Blakeney1, Y Beaulieu2, B Puliero2, M Lavigne3, A Roy3, V Massé3, P-A Vendittoli3.   

Abstract

AIMS: This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. PATIENTS AND METHODS: Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up.
RESULTS: There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery.
CONCLUSION: LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434-41.

Entities:  

Keywords:  Ceramic-on-ceramic; Large diameter head; Maxera; Monoblock cup; Total hip arthroplasty

Mesh:

Year:  2018        PMID: 30418068     DOI: 10.1302/0301-620X.100B11.BJJ-2018-0532.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  9 in total

1.  Сomparative analysis of large diameter bearing ceramic monoblock acetabular components.

Authors:  Valery Yu Murylev; Pavel M Elizarov; Aleksei V Muzychenkov; Yaroslav A Rukin; Grigory A Kukovenko; Semen S Alekseev; Michail P Elizarov
Journal:  J Orthop       Date:  2022-08-11

2.  Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans.

Authors:  Tarun Goyal; Souvik Paul; Arghya Kundu Choudhury; Tushar Gupta
Journal:  Clin Orthop Surg       Date:  2021-08-17

Review 3.  Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts.

Authors:  Pascal-André Vendittoli; Sagi Martinov; Mina Wahba Morcos; Sivan Sivaloganathan; William G Blakeney
Journal:  J Clin Med       Date:  2022-03-30       Impact factor: 4.241

4.  Whole blood titanium metal ion measurement reproducibility of two laboratories.

Authors:  Janie Barry; David Eichler; Robert Robitaille; Pascal-André Vendittoli
Journal:  Pract Lab Med       Date:  2020-05-08

5.  Letter to Editor Concerning "Total Hip Arthroplasty Using Ceramic-on-ceramic Bearing Surfaces: Long-term Assessment of Squeaking Sounds" by Kim et al. (Hip Pelvis. 2018;30(1):18-22, http://dx.doi.org/10.5371/hp.2018.30.1.18).

Authors:  Seung Jin Yoo; Young-Ho Rho; Kwang Woo Nam
Journal:  Hip Pelvis       Date:  2019-11-28

6.  Despite higher revision rate, MoM large-head THA offers better clinical scores than HR: 14-year results from a randomized controlled trial involving 48 patients.

Authors:  Lazaros Kostretzis; Martin Lavigne; Marc-Olivier Kiss; Maged Shahin; Janie Barry; Pascal-André Vendittoli
Journal:  BMC Musculoskelet Disord       Date:  2021-04-30       Impact factor: 2.362

7.  Arthroscopic evaluation and treatment of a squeaking hip. A case report.

Authors:  Jonathan Bellity; Marc Elkaïm; Didier Hannouche; Rémy Nizard
Journal:  BMC Musculoskelet Disord       Date:  2020-12-03       Impact factor: 2.362

8.  Fourth-Generation Ceramic-on-Ceramic THA in Patients with Ankylosing Spondylitis: A Minimum 10-Year Follow-Up.

Authors:  Liangliang Li; Jun Fu; Chi Xu; Ming Ni; Wei Chai; Libo Hao; Yonggang Zhou; Jiying Chen
Journal:  Orthop Surg       Date:  2022-04-18       Impact factor: 2.279

9.  Early low complication rate of ceramic-on-ceramic total hip arthroplasty by direct anterior approach.

Authors:  Paul Henri Bauwens; Camdon Fary; Elvire Servien; Sébastien Lustig; Cécile Batailler
Journal:  SICOT J       Date:  2020-08-04
  9 in total