Shane A. Smith1, Vivian C. McAlister1. 1. From the Royal Canadian Medical Service and the Department of Surgery, Western University, London, Ont.
Abstract
Background: Lower torso hemorrhage is a significant cause of death from injuries in combat. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been used to rescue patients successfully in the hospital setting, but its prehospital use is controversial. We designed a device that would be easy to use, safer in injured vessels, migration-resistant and amenable to a prehospital environment. Methods: We designed a novel, balloon-led device using common commercial materials. Thin latex rubber was reassembled in cylindrical conformation aligned to the shape of the aorta and invaginated into vinyl tubing. The catheter is placed into the femoral vessel, followed by expression of the balloon with CO2 inflation in a proximal direction to navigate and treat damaged pelvic vasculature, occluding the distal aorta. The system was tested on model aortas (both intact and injured cadaveric porcine aorta) with inline fluid flow and pressure monitoring to determine the maximum pressure the balloons could occlude. The device was also tested on a perfused human cadaveric model. Results: Flow was occluded with the balloon up to an average of 561.1 ± 124.3 mm Hg. It always ruptured before causing damage to the porcine aorta and was able to occlude injured iliac vessels and proceed to occlude the distal aorta. The device was effective in occluding the distal aorta of a perfused human cadaver. Conclusion: This novel, high-volume, low-pressure device can occlude the distal aorta in a simulated human aorta model, cadaveric porcine model and perfused human cadaver. It can occlude fluid flow to supraphysiologic pressures. It is easy to use, migration-resistant, able to navigate and treat injured pelvic vessels, and amenable to prehospital care.
Background: Lower torso hemorrhage is a significant cause of death from injuries in combat. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been used to rescue patients successfully in the hospital setting, but its prehospital use is controversial. We designed a device that would be easy to use, safer in injured vessels, migration-resistant and amenable to a prehospital environment. Methods: We designed a novel, balloon-led device using common commercial materials. Thin latex rubber was reassembled in cylindrical conformation aligned to the shape of the aorta and invaginated into vinyl tubing. The catheter is placed into the femoral vessel, followed by expression of the balloon with CO2 inflation in a proximal direction to navigate and treat damaged pelvic vasculature, occluding the distal aorta. The system was tested on model aortas (both intact and injured cadaveric porcine aorta) with inline fluid flow and pressure monitoring to determine the maximum pressure the balloons could occlude. The device was also tested on a perfused human cadaveric model. Results: Flow was occluded with the balloon up to an average of 561.1 ± 124.3 mm Hg. It always ruptured before causing damage to the porcine aorta and was able to occlude injured iliac vessels and proceed to occlude the distal aorta. The device was effective in occluding the distal aorta of a perfused human cadaver. Conclusion: This novel, high-volume, low-pressure device can occlude the distal aorta in a simulated human aorta model, cadaveric porcine model and perfused human cadaver. It can occlude fluid flow to supraphysiologic pressures. It is easy to use, migration-resistant, able to navigate and treat injured pelvic vessels, and amenable to prehospital care.
Authors: Joseph J DuBose; Thomas M Scalea; Megan Brenner; Dimitra Skiada; Kenji Inaba; Jeremy Cannon; Laura Moore; John Holcomb; David Turay; Cassra N Arbabi; Andrew Kirkpatrick; James Xiao; David Skarupa; Nathaniel Poulin Journal: J Trauma Acute Care Surg Date: 2016-09 Impact factor: 3.313
Authors: Jeremy W Cannon; Luke J Hofmann; Sean C Glasgow; Benjamin K Potter; Carlos J Rodriguez; Leopoldo C Cancio; Todd E Rasmussen; C Anton Fries; Michael R Davis; James R Jezior; Richard J Mullins; Eric A Elster Journal: J Am Coll Surg Date: 2016-07-30 Impact factor: 6.113
Authors: Anders J Davidson; Rachel M Russo; Viktor A Reva; Megan L Brenner; Laura J Moore; Chad Ball; Eileen Bulger; Charles J Fox; Joseph J DuBose; Ernest E Moore; Todd E Rasmussen Journal: J Trauma Acute Care Surg Date: 2018-01 Impact factor: 3.313
Authors: Jonathan J Morrison; Adam Stannard; Todd E Rasmussen; Jan O Jansen; Nigel R M Tai; Mark J Midwinter Journal: J Trauma Acute Care Surg Date: 2013-08 Impact factor: 3.313
Authors: Nori L Bradley; W Robert Leeper; Derek Roberts; Chad G Ball; Andrew Beckett; Paul Engels; Emilie Joos; Kosar Khwaja; Andrew Kirkpatrick; Jacinthe Lampron; Sam Minor; Neil Parry; Joao Neto Rezende; Sandy Widder; Najma Ahmed; Lawrence Gillman; David Gomez; Morad Hameed; Michael Kim; Patrick Murphy; Rahima Nenshi; Timothy Rice; Kelly Vogt Journal: Can J Surg Date: 2022-05-11 Impact factor: 2.840
Authors: Stephanie Jarvis; Michael Kelly; Charles Mains; Chad Corrigan; Nimesh Patel; Matthew Carrick; Mark Lieser; Kaysie Banton; David Bar-Or Journal: Patient Saf Surg Date: 2019-12-13
Authors: Adenauer Marinho de Oliveira Góes; Rosa Helena de Figueiredo Chaves; Ismari Perini Furlaneto; Emanuelle de Matos Rodrigues; Flávia Beatriz Araújo de Albuquerque; Jacob Hindrik Antunes Smit; Carolina Pinheiro de Oliveira; Simone de Campos Vieira Abib Journal: J Vasc Bras Date: 2021-05-14