Literature DB >> 30415580

7-year results of primary total hip arthroplasty with the uncemented Avenir stem.

Roger Erivan1, Guillaume Villatte1, Jean-Michel Brientini2, David Kreider3, Stéphane Descamps1, Stéphane Boisgard1.   

Abstract

AIMS: The aim of the present study was to evaluate the 7-year functional outcome and radiographic results of primary total hip arthroplasties (THAs) performed with the uncemented Avenir stem. PATIENTS AND METHODS: Between January 2006 and October 2008, 100 consecutive primary hips in 92 patients were enrolled at 2 centres. The mean age at operation was 58.5 years (27-87 years). Mini-incision (50%) and standard approaches (50%) were used to implant 22 standard and 78 lateralised stems.
RESULTS: The 7-year Kaplan-Meier survival rate was 98.9% (95% CI, 92.9-99.8) with stem revision for any reason as endpoint. No stem related complications occurred. 1 stem revision was due to deep infection at 51 months post-op. We had 4 acetabular revisions. The mean Harris Hip Score (HHS) at 7 years follow-up was 93.1 points (60-100). Radiographic analysis showed 2 patients had non-progressive radiolucent lines and no patient had any signs of stem subsidence or loosening.
CONCLUSION: The 7-year implant survival and the functional outcomes for THA performed with the study device are excellent and were in line with those documented for comparable contemporary uncemented fully HA-coated stems. Longer term follow-up of this consecutive series needs to be performed.

Entities:  

Keywords:  Aseptic loosening; cohort follow-up; hip arthroplasty; primary hip replacement; uncemented stem

Mesh:

Year:  2018        PMID: 30415580     DOI: 10.1177/1120700018810211

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

1.  Primary total hip replacement in Ficat-Arlet stage 3 and 4 osteonecrosis: a retrospective study at a minimum 12-year follow-up.

Authors:  Roger Erivan; Thomas Caputo; Hicham Riouach; Guillaume Villatte; Bruno Perreira; Stéphane Descamps; Stéphane Boisgard
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-02-27

2.  Survival and performance of a dual tapered-wedge fully HA-coated press fit femoral stem.

Authors:  Ramakanth R Yakkanti; Dylan N Greif; Dennis J Vanden Berge; Raymond P Robinson
Journal:  Arch Orthop Trauma Surg       Date:  2022-03-03       Impact factor: 3.067