Magnetic resonance imaging with cochlear implants and auditory brainstem implants: Are we truly practicing MRI safety?

Matthew Shew1, Helena Wichova1, James Lin1, Luke N Ledbetter2, Hinrich Staecker1.   

Abstract

OBJECTIVE: Our objective is to evaluate the safety in patients with cochlear implants (CIs) and auditory brainstem implants (ABI) undergoing 1.5 Tesla (T) magnetic resonance imaging (MRI). Secondly, we want to raise awareness on CI and MRI safety, and advocate for continued improvement and advancement to minimize morbidity for our CI patients.
METHODS: Retrospective case series from 2006 to 2018 at a single tertiary academic center. Data was collected on patients with CI or auditory brainstem implants undergoing MRI. Outcomes collected include demographic data, age at time of MRI, MRI characteristics, complications, CI manufacturer, and image quality.
RESULTS: Eighteen patients with CI or ABI collectively underwent a total of 62 MRI scans. Five of 15 (33%) CI patients with magnet had complications: five total of 24 MRI scans (21%). Two patients had magnet removal prior to 29 MRI scans without complications. Four of five MRI-related complications were equipped with a U.S. Food and Drug Administration-approved head wrap. Three of five required a trip to the operating room to explore and reposition the CI magnet; two could not complete MRI secondary to pain. Of the complications, two were Cochlear (Sydney, Australia), two Advanced Bionics (Valencia, CA), and one MED-EL (Innsbruck, Austria). Synchrony model (MED-EL) had 0 of seven complications, with a total of 19 MRI scans, which features a freely rotating and self-aligning magnet.
CONCLUSION: Our series offers a diverse number of CI manufacturers and is in accordance with other literature that CI MRI-related adverse events are occurring at an unacceptable frequency. We can promote CI MRI safety through our institutions' MRI CI patient protocols, raise awareness that diagnostic MRI benefits must outweigh CI-related complications, and advocate for continued industry technological innovation. LEVEL OF EVIDENCE: 4 Laryngoscope, 129:482-489, 2019.
© 2018 The American Laryngological, Rhinological and Otological Society, Inc.

Entities:  

Keywords:  Cochlear implant; MRI safety; NF2; magnet displacement

Mesh:

Year:  2018        PMID: 30412276     DOI: 10.1002/lary.27516

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  8 in total

1.  Neural Activity During Audiovisual Speech Processing: Protocol For a Functional Neuroimaging Study.

Authors:  András Bálint; Wilhelm Wimmer; Marco Caversaccio; Stefan Weder
Journal:  JMIR Res Protoc       Date:  2022-06-21

2.  Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report.

Authors:  Stefan K Plontke; Laura Fröhlich; Sebastian Cozma; Assen Koitschev; Katrin Reimann; Rainer Weiß; Gerrit Götze; Ingmar Seiwerth; Sabrina Kösling; Torsten Rahne
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-06-05       Impact factor: 2.503

3.  MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study.

Authors:  Pietro Canzi; Federico Aprile; Anna Simoncelli; Marco Manfrin; Marianna Magnetto; Elvis Lafe; Domenico Minervini; Irene Avato; Simone Terrani; Andrea Scribante; Dzemal Gazibegovic; Marco Benazzo
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-11-18       Impact factor: 2.503

4.  Two-phase survey on the frequency of use and safety of MRI for hearing implant recipients.

Authors:  Paul van de Heyning; Griet Mertens; Vedat Topsakal; Ruben de Brito; Wilhelm Wimmer; Marco D Caversaccio; Stefan Dazert; Stefan Volkenstein; Mario Zernotti; Lorne S Parnes; Hinrich Staecker; Iain A Bruce; Gunesh Rajan; Marcus Atlas; Peter Friedland; Piotr H Skarzynski; Serafima Sugarova; Vladislav Kuzovkov; Abdulrahman Hagr; Robert Mlynski; Joachim Schmutzhard; Shin-Ichi Usami; Luis Lassaletta; Javier Gavilán; Benoit Godey; Christopher H Raine; Rudolf Hagen; Georg M Sprinzl; Kevin Brown; Wolf-Dieter Baumgartner; Eva Karltorp
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-03-31       Impact factor: 2.503

5.  Magnet and receiver-stimulator displacement after cochlear implantation: Clinical characters and management approaches.

Authors:  Asma Alahmadi; Saad Alenzi; Mohammed Alsheikh; Saeed Alghamdi; Mostafa E Morra; Khalid M Badr
Journal:  Saudi Med J       Date:  2021-08       Impact factor: 1.422

Review 6.  Safety of active auditory implants in magnetic resonance imaging.

Authors:  Guy Fierens; Nina Standaert; Ronald Peeters; Christ Glorieux; Nicolas Verhaert
Journal:  J Otol       Date:  2021-01-06

7.  Management of transmodiolar and transmacular cochleovestibular schwannomas with and without cochlear implantation.

Authors:  S K Plontke; P Caye-Thomasen; C Strauss; S Kösling; G Götze; U Siebolts; D Vordermark; L Wagner; L Fröhlich; T Rahne
Journal:  HNO       Date:  2021-01       Impact factor: 1.284

8.  The role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system.

Authors:  Pietro Canzi; Marianna Magnetto; Anna Simoncelli; Marco Manfrin; Federico Aprile; Elvis Lafe; Elena Carlotto; Irene Avato; Andrea Scribante; Lorenzo Preda; Marco Benazzo
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-08-09       Impact factor: 2.503

  8 in total