Medical Ultrasound Disinfection and Hygiene Practices: WFUMB Global Survey Results.

Susan Campbell Westerway1, Jocelyne M Basseal2, Jacques S Abramowicz3.   

Abstract

As ultrasound technology rapidly evolves and is used more frequently in every area of medical diagnosis and treatment, it may be overlooked as a potential vector in the transmission of a health care-associated infection. A survey on disinfection and hygiene practice in medical ultrasound was disseminated via the World Federation for Ultrasound in Medicine and Biology (WFUMB) to its six member federations and associated ultrasound societies globally. One thousand twenty-nine responses were obtained across a broad range of ultrasound practitioners. A total of 76% of respondents used transducer covers every time to scan open wounds and 71% when blood and bodily fluids were present or for an interventional procedure. Approved high-level disinfectants are not always used, even when blood comes into contact with the transducer or after endocavity scans. Alcohol-based wipes were used by many respondents to clean both external transducers and endocavity transducers. Open-ended responses indicated that a large caseload hindered the time required for cleaning and that access to clear guidelines would be beneficial. Global survey results indicate that some users do not comply with disinfection practice, and there is a gap in knowledge on basic infection prevention and control education within the ultrasound unit. As the infectious status of a patient is not often disclosed prior to an ultrasound examination, training in suitable protocols for the cleaning and disinfection of ultrasound equipment is imperative to mitigate the risk of potential infection.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Disinfection; Guidelines; Infection control; Survey; Transducers; Ultrasound

Mesh:

Year:  2018        PMID: 30409470     DOI: 10.1016/j.ultrasmedbio.2018.09.019

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

1.  World Federation for Ultrasound in Medicine and Biology Position Statement: How to Perform a Safe Ultrasound Examination and Clean Equipment in the Context of COVID-19.

Authors:  J S Abramowicz; J M Basseal
Journal:  Ultrasound Med Biol       Date:  2020-04-04       Impact factor: 2.998

2.  Emergency ward ultrasound: clinical audit on disinfection practices during routine and sterile examinations.

Authors:  A Andolfo; R Maatoug; N Peiffer-Smadja; C Fayolle; K Blanckaert
Journal:  Antimicrob Resist Infect Control       Date:  2021-01-30       Impact factor: 4.887

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.