Literature DB >> 30408138

Digital vs Conventional Workflow for Screw-Retained Single-Implant Crowns: A Comparison of Key Considerations.

Adolfo Di Fiore, Paolo Vigolo, Lorenzo Graiff, Edoardo Stellini.   

Abstract

PURPOSE: To evaluate patient perception and operating time of digital (DW) and conventional (CW) workflows for the rehabilitation of a screw-retained, single-implant crown.
MATERIALS AND METHODS: A convenience sample of 10 patients with single implants in posterior sites was recruited for treatment with screw-retained single crowns, fabricated with either a DW or a CW protocol. Operating time and clinical adjusting time were recorded with a stopwatch, and patient preference and self-perception of the esthetic outcome were evaluated with a visual analog scale.
RESULTS: The mean operating time for the DW crowns was 16:21 minutes and for the CW crowns was 28:28 minutes. The mean total adjustment times were 118.1 seconds for the DW protocol and 181.5 seconds for the CW protocol. The mean score regarding self-perception of the esthetic outcome was 73 for DW crowns and 69 for CW crowns; for discomfort, the mean score was 15.5 for DW and 62 for CW.
CONCLUSION: The DW approach resulted in a time reduction for both the impression phase and operative time.

Entities:  

Mesh:

Year:  2018        PMID: 30408138     DOI: 10.11607/ijp.5938

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  10 in total

1.  A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners.

Authors:  Irina Karakas-Stupar; Nicola Ursula Zitzmann; Tim Joda
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

2.  Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study.

Authors:  Adolfo Di Fiore; Lorenzo Graiff; Gianpaolo Savio; Stefano Granata; Michele Basilicata; Patrizio Bollero; Roberto Meneghello
Journal:  Int J Environ Res Public Health       Date:  2022-04-13       Impact factor: 4.614

Review 3.  Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review.

Authors:  Sven Mühlemann; Jenni Hjerppe; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

4.  The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software.

Authors:  Se-Won Park; Yong-Do Choi; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

5.  Trueness of digital implant impressions based on implant angulation and scan body materials.

Authors:  Jae-Hyun Lee; Jae-Hwi Bae; Su Young Lee
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

Review 6.  Effect of Toothpaste on the Surface Roughness of the Resin-Contained CAD/CAM Dental Materials: A Systematic Review.

Authors:  Adolfo Di Fiore; Edoardo Stellini; Michele Basilicata; Patrizio Bollero; Carlo Monaco
Journal:  J Clin Med       Date:  2022-01-31       Impact factor: 4.241

7.  Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based.

Authors:  Tobias Graf; Jan-Frederik Güth; Christian Diegritz; Anja Liebermann; Josef Schweiger; Oliver Schubert
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

8.  Think Digital-The New Era in the Dentistry Field.

Authors:  Adolfo Di Fiore
Journal:  J Clin Med       Date:  2022-07-14       Impact factor: 4.964

9.  Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction.

Authors:  Ana Larisse Carneiro Pereira; Vitória Ramos Medeiros; Maria de Fátima Trindade Pinto Campos; Annie Karoline Bezerra de Medeiros; Burak Yilmaz; Adriana da Fonte Porto Carreiro
Journal:  J Adv Prosthodont       Date:  2022-08-29       Impact factor: 1.989

10.  Impact of Matching Point Selections on Image Registration Accuracy between Optical Scan and Computed Tomography.

Authors:  Hai Yen Mai; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2020-08-04       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.