Literature DB >> 30401375

Diffusion-Weighted Magnetic Resonance Imaging in Liver Graft Rejection.

C-C Lin3, H-Y Ou1, Y-H Chuang1, H-J Chiang1, C-C Yu1, M Lazo2, L L-C Tsang1, T-L Huang1, C-C Lin3, C-L Chen3, Y-F Cheng4.   

Abstract

OBJECTIVE: The purpose of this study is to evaluate the use of diffusion-weighted magnetic resonance imaging (DWMRI) in the assessment of graft rejection after liver transplantation (LT).
METHODS: From June 2017 to January 2018, 32 patients were included in the study with a mean age of 52.3 years. All patients underwent LT. The DWMRI was performed using the apparent diffusion coefficient map and measuring the different b-values (b-400, b-600, b-800, and b-1000). These measurements were compared with the histopathology results. Statistical analysis included t test, analysis of variance, and area under the curve for receiver operating characteristic (ROC).
RESULTS: There were 17 patients without rejection and 15 patients with liver graft rejection diagnosed by histopathology. The mean (SD) results between the nonrejection and rejection groups were as follows: b-400 = 1.568 (0.265) vs 1.519 (0.119) (P = .089), b-600 = 1.380 (0.181) vs 1.284 (0.106) (P = .039), b-800 = 1.262 (0.170) vs 1.170 (0.086) (P = .035), b-1000 = 1.109 (0.129) vs 1.098 (0.078) (P = .095); B-values × 10-3 mm2/s. Only b-600 (P = .04) and b-800 (P = .04) values have significant differences between the 2 groups. B-600 showed 90.48% sensitivity and 83.33% specificity (ROC area under the curve = 0.784; P < .001), and b-800 showed 90.38% sensitivity and 83.03% specificity (ROC area under the curve = 0.816; P < .001). The values obtained with the apparent diffusion coefficient in b-800 were clearly differentiated between the mild, moderate, and severe degrees of rejection (P < .001).
CONCLUSION: Measurement of b-600 and b-800 values using DWMRI may be used for the diagnosis of graft rejection after LT.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30401375     DOI: 10.1016/j.transproceed.2018.04.018

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  2 in total

1.  Optimized Parameters of Diffusion-Weighted MRI for Prediction of the Response to Neoadjuvant Chemoradiotherapy for Locally Advanced Rectal Cancer.

Authors:  Jie Li; Jia Wang; Jing Pang; Shougen Cao; Jingjing Chen; Wenjian Xu
Journal:  Biomed Res Int       Date:  2019-10-13       Impact factor: 3.411

2.  Apparent diffusion coefficient for the prediction of tumor response to neoadjuvant chemo-radiotherapy in locally advanced rectal cancer.

Authors:  Mengjing Zhao; Lihao Zhao; Han Yang; Yuxia Duan; Gang Li
Journal:  Radiat Oncol       Date:  2021-01-20       Impact factor: 3.481

  2 in total