| Literature DB >> 30398069 |
Yue Qiu1, Ding Yuan2, Ye Wang1, Jun Wen3, Tinghui Zheng1.
Abstract
This paper describes a systematic investigation on the hemodynamic environment in a patient-specific AAA with tortuous common iliac artery(CIA) and external iliac artery (EIA). 3D reconstructions from CT scans and subsequent computational simulation are carried out. It is found out that the Newtonian and non-Newtonian models have very similar flow field and WSS distribution. More importantly, it is revealed that the torturous CIA maintained its helical flow. It is concluded that the assumption of Newtonian blood is adequate in capturing the intra-aneurysmal hemodynamics. Moreover, it is speculated that the physiological spiral flow protects the twisted CIA from the thrombosis formation.Entities:
Keywords: CFD; abdominal aortic aneurysm; hemodynamics; iliac tortuosity; thrombosis
Mesh:
Year: 2018 PMID: 30398069 DOI: 10.1080/10255842.2018.1522531
Source DB: PubMed Journal: Comput Methods Biomech Biomed Engin ISSN: 1025-5842 Impact factor: 1.763