Literature DB >> 30397365

Low level determination of gallium isotopes by ICP-QQQ.

Brian P Jackson1.   

Abstract

Determination of low concentrations of Ga in environmental or biological samples can benefit from interference free measurement of both Ga isotopes. Unfortunately, both isotopes have potential interferences, i.e doubly charged Ba at m/z 69 and MnO at 71. Analysis using collision and reaction gases by ICP-QQQ as an alternative to HR-ICP-MS is investigated here using conventional nebulization and a desolvating nebulizer. Analysis at m/z 71 is not appreciably affected by MnO at 200 ug/l Mn or in either water reference material; excellent detection limits of < 0.1 ng/l were obtained for He, H2, or on-mass O2 and NH3 gas modes. Analysis of Ga at m/z 69 was severely affected by doubly charged Ba across all gas modes except +17 mass-shift (i.e. 69 - 86) NH3 gas mode. Despite Ga being only 1-2% reactive at the 69-86 mass shift, the doubly-charged interference was not mass-shifted and detection limits of < 1 ng/l and precise and accurate quantification of two water reference materials and nine natural water samples were achievable for this analysis mode.

Entities:  

Year:  2018        PMID: 30397365      PMCID: PMC6214485          DOI: 10.1039/C8JA00073E

Source DB:  PubMed          Journal:  J Anal At Spectrom        ISSN: 0267-9477            Impact factor:   4.023


  4 in total

1.  Measurement of arsenic and gallium content of gallium arsenide semiconductor waste streams by ICP-MS.

Authors:  Keith W Torrance; Helen E Keenan; Andrew S Hursthouse; David Stirling
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2010       Impact factor: 2.269

2.  Determination of gallium originated from a gallium-based anticancer drug in human urine using ICP-MS.

Authors:  Darya G Filatova; Irina F Seregina; Lidia S Foteeva; Vladimir V Pukhov; Andrei R Timerbaev; Mikhail A Bolshov
Journal:  Anal Bioanal Chem       Date:  2011-03-01       Impact factor: 4.142

3.  The suitability of gallium as a substitute for aluminum in tracing experiments.

Authors:  Rachel C Walton; Keith N White; Francis Livens; Catherine R McCrohan
Journal:  Biometals       Date:  2009-11-25       Impact factor: 2.949

Review 4.  Evaluation of the carcinogenicity of gallium arsenide.

Authors:  Ernst M Bomhard; Heinz-Peter Gelbke; Hermann Schenk; Gary M Williams; Samuel M Cohen
Journal:  Crit Rev Toxicol       Date:  2013-05       Impact factor: 5.635

  4 in total
  2 in total

1.  An evaluation of M2+ interference correction approaches associated with As and Se in ICP-MS using a multi-day dataset along with ICP-MS/MS/HR-ICP-MS based analysis and hierarchical modeling as a means of assessing bias in fortified drinking waters and single component matrices.

Authors:  Skyler W Smith; Roy W Martin; Nicole Hanks; Patricia A Creed; Kasey Kovalcik; Robert A Wilson; Kevin Kubachka; Judith A Brisbin; Julio A Landero Figueroa; John T Creed
Journal:  J Anal At Spectrom       Date:  2022-03-18       Impact factor: 4.351

2.  Analytical considerations associated with implementing M2+ correction factors to address false positives on As and Se within U.S. EPA method 200.8.

Authors:  Skyler W Smith; Nicole Hanks; Patricia A Creed; Kasey Kovalcik; Robert A Wilson; Kevin Kubachka; Judith A Brisbin; Julio Landero Figueroa; John T Creed
Journal:  J Anal At Spectrom       Date:  2019-10-01       Impact factor: 4.023

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.