Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part III: Marginal and internal fit.

Goran I Benic1, Irena Sailer2, Marco Zeltner3, Janine N Gütermann4, Mutlu Özcan5, Sven Mühlemann3.   

Abstract

STATEMENT OF PROBLEM: Trials comparing the overall performances of digital and conventional workflows in restorative dentistry are lacking.
PURPOSE: The purpose of the third part of this clinical study was to test whether the fit of zirconia 3-unit frameworks for fixed partial dentures fabricated with fully digital workflows differed from that of metal frameworks fabricated with the conventional workflow.
MATERIAL AND METHODS: In each of 10 participants, 4 fixed-partial-denture frameworks were fabricated for the same abutment teeth according to a randomly generated sequence. Digital workflows were applied for the fabrication of 3 zirconia frameworks with Lava, iTero, and Cerec infiniDent systems. The conventional workflow included a polyether impression, manual waxing, the lost-wax technique, and the casting of a metal framework. The discrepancies between the frameworks and the abutment teeth were registered using the replica technique with polyvinyl siloxane. The dimensions of the marginal discrepancy (Discrepancymarginal) and the internal discrepancy in 4 different regions of interest (Discrepancyshoulder, Discrepancyaxial, Discrepancycusp, and Discrepancyocclusal) were assessed using a light microscope. Post hoc t tests with Bonferroni correction were applied to detect differences (α=.05).
RESULTS: Discrepancyshoulder was 96.1 ±61.7 μm for the iTero, 106.9 ±96.0 μm for the Lava, 112.2 ±76.7 μm for the Cerec infiniDent, and 126.5 ±91.0 μm for the conventional workflow. The difference between the iTero and the conventional workflow was statistically significant (P=.029). Discrepancyocclusal was 153.5 ±66.8 μm for the iTero, 203.3 ±127.9 μm for the Lava, 179.7 ±63.1 μm for the Cerec infiniDent, and 148.8 ±66.8 μm for the conventional workflow. Discrepancyocclusal was significantly lower for the conventional workflow than for the Lava and the Cerec infindent workflows (P<.01). The iTero resulted in significantly lower values of Discrepancyocclusal than the Lava and the Cerec infiniDent workflows (P<.01).
CONCLUSIONS: In terms of framework fit in the region of the shoulder, digitally fabricated zirconia 3-unit frameworks presented similar or better fit than the conventionally fabricated metal frameworks. In the occlusal regions, the conventionally fabricated metal frameworks achieved a more favorable fit than the CAD-CAM zirconia frameworks.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30396708     DOI: 10.1016/j.prosdent.2018.05.014

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  A within-subject comparison of the conventional clasp-retained with attachment-retained removable partial dentures.

Authors:  Ahmed Y Alqutaibi
Journal:  J Taibah Univ Med Sci       Date:  2020-06-29

2.  Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures.

Authors:  Francesco Mangano; Carlo Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Scanning       Date:  2019-08-22       Impact factor: 1.932

Review 3.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

4.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

5.  Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans.

Authors:  Irem Gokce Uluc; Mustafa Baris Guncu; Guliz Aktas; Ilser Turkyilmaz
Journal:  J Dent Sci       Date:  2021-07-30       Impact factor: 2.080

Review 6.  Accuracy of marginal adaptation of posterior fixed dental prosthesis made from digital impression technique: A systematic review.

Authors:  Hanuman Chalapathi Kumar; Tannamala Pavan Kumar; Surapaneni Hemchand; Chinni Suneelkumar; Anirudhan Subha
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

7.  Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study.

Authors:  Francesco Guido Mangano; Oleg Admakin; Matteo Bonacina; Henriette Lerner; Vygandas Rutkunas; Carlo Mangano
Journal:  BMC Oral Health       Date:  2020-09-22       Impact factor: 2.757

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.