Literature DB >> 30393270

Preserved Vasoconstriction and Relaxation of Saphenous Vein Grafts Obtained by a No-Touch Technique for Coronary Artery Bypass Grafting.

Toshiyuki Yamada1,2, Takeshi Adachi3, Yasuo Ido3, Nobuyuki Masaki3, Takumi Toya3, Tomoya Uchimuro4, Kosaku Nishigawa4, Hisao Suda5, Motohiko Osako2, Masataka Yamazaki1,4, Shuichiro Takanashi4, Hideyuki Shimizu1.   

Abstract

BACKGROUND: To obtain a saphenous vein graft (SVG) for coronary artery bypass grafting (CABG), the benefit of using a no-touch (NT) technique in vascular function has not been fully investigated. Methods and 
Results: The pathological and physiological functions of human SVGs with a NT technique to preserve the perivascular adipose tissue (PVAT) and ones obtained by using a conventional (CON) technique removing PVAT, were examined. Immunohistochemistry of the section of SVGs showed that the phosphorylation of endothelial nitric oxide synthase in the endothelium of the NT group was more responsive to vascular endothelial growth factor. A myograph of SVGs showed greater contraction with phenylephrine in the NT group. However, the strong contraction was eliminated in SVGs taken by electrocautery. In the 10 patients whose SVGs were taken without electrocautery, endothelial-dependent relaxation with bradykinin was apparently increased in the CON group more than in the NT group. Smooth muscle relaxation with nitroprusside was higher in the CON group at the lower concentrations; however, the relaxation became greater in the NT group at the high concentrations. Therefore, the effect of neutralizing PVAT-released factors in the both groups was further examined. After medium of NT and CON were exchanged in half, relaxation of SVGs was immediately restored in the NT group.
CONCLUSIONS: The results suggest that the NT technique preserves the functions of vasoconstriction and relaxation. Also, the presence of PVAT-released vasoconstrictive factors was suspected.

Entities:  

Keywords:  Coronary artery bypass grafting; Nitric oxide; No-touch technique; Perivascular adipose tissue; Saphenous vein graft

Mesh:

Substances:

Year:  2018        PMID: 30393270     DOI: 10.1253/circj.CJ-18-0714

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  1 in total

1.  No-touch saphenous vein graft harvesting technique for coronary artery bypass grafting.

Authors:  Yu Inaba; Masataka Yamazaki; Masatoshi Ohono; Kentaro Yamashita; Hiroaki Izumida; Kanako Hayashi; Tatsuo Takahashi; Naritaka Kimura; Tsutomu Ito; Hideyuki Shimizu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-08-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.