The Effect of Sacrificing the Posterior Cruciate Ligament in Total Knee Arthroplasties That Use a Highly Congruent Polyethylene Component.

Benjamin M Stronach1, Jeremy C Adams1, LaRita C Jones1, Sean M Farrell2, Josie M Hydrick1.   

Abstract

BACKGROUND: There is continued debate regarding retention versus sacrificing of the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA). We sought to determine if there was a difference in range of motion (ROM) after TKA between patients with PCL sacrifice versus PCL retention when using a highly congruent polyethylene insert.
METHODS: We conducted an Institutional Review Board approved retrospective study of consecutive patients receiving TKA using the same implant with a highly congruent polyethylene component implanted by one surgeon from November 2013 to January 2016. Patients were placed in 2 groups based on whether the PCL was intact or released at the time of surgery. Patient charts were reviewed for age, body mass index, PCL status at surgery (incompetent, kept intact, or released), and preoperative/postoperative knee ROM.
RESULTS: Both groups were similar in average age (60.5 vs 60.6, respectively) and body mass index (33.3 vs 32.6, respectively). Postoperative tibial slope (5.5° PCL release, 6.6° PCL retained, P = .028) was the only alignment variable reaching significance; all other alignment and motion variables were similar.
CONCLUSION: Results indicate that the PCL can be successfully retained with the use of a congruent bearing design, with no evident limitation in postoperative ROM or loss of stability due to the bearing in comparison to patients who undergo PCL release.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  highly congruent polyethylene component; knee balancing; posterior cruciate ligament retention; posterior cruciate ligament sacrifice; total knee arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 30392900     DOI: 10.1016/j.arth.2018.10.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

Review 1.  Biomechanics and Outcomes of Modern Tibial Polyethylene Inserts.

Authors:  Darshan Shah; Taylor Bates; Craig Kampfer; Donald Hope
Journal:  Curr Rev Musculoskelet Med       Date:  2022-04-06

2.  Equivalent outcomes of ultra-congruent and standard cruciate-retaining inserts in total knee arthroplasty.

Authors:  Karthik Vishwanathan; Srinivas B S Kambhampati; Raju Vaishya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-01-11       Impact factor: 4.114

3.  The effect of sacrificing the posterior cruciate ligament on total knee arthroplasty with cruciate retaining highly congruent rotating platform prosthesis.

Authors:  Long Chen; Jie Xu; Yuan Lin; Fen Qi Luo; Yu Guo Yu
Journal:  J Orthop Surg Res       Date:  2021-05-07       Impact factor: 2.359

4.  Tibial baseplate position and posterior cruciate ligament status impact patient-reported outcomes in conforming dual-pivot bearing total knee arthroplasty.

Authors:  Joseph A Madden; Payton K Arnold; Leonard T Buller; Evan R Deckard; R Michael Meneghini
Journal:  Arthroplast Today       Date:  2021-10-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.