Literature DB >> 30391560

Carbon monofilament electrodes for unit recording and functional MRI in same subjects.

Miguel R Chuapoco1, Mankin Choy1, Florian Schmid1, Ben A Duffy1, Hyun Joo Lee1, Jin Hyung Lee2.   

Abstract

Extracellular electrophysiology and functional MRI are complementary techniques that provide information about cellular and network-level neural activity, respectively. However, electrodes for electrophysiology are typically made from metals, which cause significant susceptibility artifacts on MR images. Previous work has demonstrated that insulated carbon fiber bundle electrodes reduce the volume of magnetic susceptibility artifacts and can be used to record local field potentials (LFP), but the relatively large diameter of the probes make them unsuitable for multi- and single-unit recordings. Although single carbon fiber electrodes have recently been used to record single-unit activity, these probes require modifications in order to aid insertion and the use of these probes in fMRI has yet to be validated. Therefore, there is a need for a single-carbon fiber electrode design that (1) minimizes the volume of the susceptibility artifact, (2) can record from a wide frequency band that includes LFP and multi- and single-unit recording, and (3) is practical to insert without additional modifications. Here, we demonstrate that carbon-fiber electrodes made from single carbon monofilaments (35 μm in diameter) meet all of these criteria. Carbon monofilament electrodes modified with the conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) have lower impedances and higher signal-to-noise ratio recordings than platinum-iridium electrodes, a current gold standard for chronic single-unit recording. Furthermore, these probes distort a significantly smaller volume of voxels compared to tungsten and platinum-iridium electrodes in agarose phantom and in vivo MR images, leading to higher contrast-to-noise ratio in regions proximal to the electrode implantation site during fMRI. Collectively, this work establishes that carbon monofilaments are a practical choice for combined electrophysiology-fMRI experiments.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Keywords:  Carbon monofilament; Electrode; PEDOT; Single-unit recording; fMRI

Mesh:

Substances:

Year:  2018        PMID: 30391560     DOI: 10.1016/j.neuroimage.2018.10.082

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  3 in total

Review 1.  Nanotechnology in neurosurgery: a systematic review.

Authors:  Dimitrios Giakoumettis; Spyros Sgouros
Journal:  Childs Nerv Syst       Date:  2021-01-18       Impact factor: 1.475

Review 2.  Multi-scale neural decoding and analysis.

Authors:  Hung-Yun Lu; Elizabeth S Lorenc; Hanlin Zhu; Justin Kilmarx; James Sulzer; Chong Xie; Philippe N Tobler; Andrew J Watrous; Amy L Orsborn; Jarrod Lewis-Peacock; Samantha R Santacruz
Journal:  J Neural Eng       Date:  2021-08-16       Impact factor: 5.043

3.  Focal electrical stimulation on an alcohol disorder model using magnetic resonance imaging-compatible chronic neural monopolar carbon fiber electrodes.

Authors:  Alejandra Lopez-Castro; Diego Angeles-Valdez; Gerardo Rojas-Piloni; Eduardo A Garza-Villarreal
Journal:  Front Neurosci       Date:  2022-09-29       Impact factor: 5.152

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.