Literature DB >> 30391328

Endovascular Treatment of Ruptured Tiny Intracranial Aneurysms with Low-Profile Visualized Intraluminal Support Device.

Pei Wu1, Pinar Eser Ocak2, Dianhong Wang3, Umut Ocak4, Shancai Xu5, Yuchen Li6, Tongyu Zhang7, Huaizhang Shi8.   

Abstract

BACKGROUND: Ruptured tiny intracranial aneurysms (TIAs) have been challenging both for endovascular and neurosurgical interventions. Thus, we aimed to evaluate the safety and efficacy of low-profile visualized intraluminal support (LVIS) device in the treatment of ruptured TIAs (rTIAs).
MATERIAL AND METHODS: Among 761 intracranial aneurysms which were treated either surgically or endovascularly, 32 rTIAs underwent stent-assisted coiling with LVIS device between 2014 and 2017. Patient data were reviewed retrospectively. Clinical and radiological outcomes were recorded at discharge and mid-term follow-up.
RESULTS: Mean patient ages were 53 ± 14.5 years. Mean aneurysm size was 2.28 ± .53 mm (range, 1-2.9 mm) with a mean dome:neck ratio of 1.08 (range, .75-2.14). The LVIS stents were successfully implanted in all patients. Mean follow-up period was 9.3 ± 1.9 months (range, 6-15 months). Immediate angiographic evaluation demonstrated complete occlusion in 13 (40.6%) patients, while neck remnant and residual sac were observed in 12 (37.5%) and 7 (21.9%), respectively. All patients had moderate disability (mRS 2-3) at discharge. Number of aneurysms with complete occlusion significantly increased and 82.1% of the patients (23 of 28) demonstrated complete occlusion at follow-up (P = .0015). Among these, 27 had good outcome (mRS 0-1; 96.9%) with significant improvement compared to discharge (P = .0001). There was no recurrence or enlargement of the residual aneurysms. Additionally, there were no procedure-related complications except the one (3.6%) showing asymptomatic stenosis of the posterior cerebral artery in follow-up imagings.
CONCLUSIONS: Stent-assisted coiling of rTIAs with LVIS device provides high rates of technical success and complete occlusion at mid-term follow-up with an excellent safety profile.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Keywords:  Aneurysm; LVIS stent; angiography; coil

Mesh:

Year:  2018        PMID: 30391328     DOI: 10.1016/j.jstrokecerebrovasdis.2018.09.052

Source DB:  PubMed          Journal:  J Stroke Cerebrovasc Dis        ISSN: 1052-3057            Impact factor:   2.136


  3 in total

1.  Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms: comparison of LVIS stents with laser-cut stents.

Authors:  Gaici Xue; Qiao Zuo; Xiaoxi Zhang; Haishuang Tang; Rui Zhao; Qiang Li; Yibin Fang; Pengfei Yang; Bo Hong; Yi Xu; Qinghai Huang; Jianmin Liu
Journal:  Chin Neurosurg J       Date:  2021-03-03

2.  Endovascular treatment of ruptured tiny aneurysms.

Authors:  Joon Hyuk Kim; Chang Hwa Choi; Jae Il Lee; Tae Hong Lee; Jun Kyeung Ko
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2019-06-30

3.  AngioSuite-Assisted Volume Calculation and Coil Use Prediction in the Endovascular Treatment of Tiny Volume Intracranial Aneurysms.

Authors:  Zhihua Du; Bin Lv; Xiangyu Cao; Xinfeng Liu; Rongju Zhang; Hui Su; Jun Wang
Journal:  Biomed Res Int       Date:  2021-07-29       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.