Wrong-Patient Blood Transfusion Error: Leveraging Technology to Overcome Human Error in Intraoperative Blood Component Administration.

Nadia B Hensley, Colleen G Koch, Peter J Pronovost, Bommy Hong Mershon, Joan Boyd, Susan Franklin, Dana Moore, Kristen Sheridan, Anne Steele, Tracey L Stierer.   

Abstract

BACKGROUND: Confirmation of match between patient and blood product remains a manual process in most operating rooms (ORs), and documentation of dual-signature verification remains paper based in most medical institutions. A sentinel event at Johns Hopkins Hospital in which a seriously ill patient undergoing an emergent surgical procedure was transfused with a unit of incompatible red blood cells that had been intended for another patient in an adjacent OR led the hospital to conduct a quality improvement project to improve the safety of intraoperative blood component transfusions.
METHODS: A multidisciplinary quality improvement project team led a four-phase implementation of bedside bar code transfusion verification (BBTV) for intraoperative blood product administration. Manual random sample audits of blood component transfusions were used to examine accuracy of documentation from July 2014 through June 2016. After the transition to the Epic anesthesia information management system (AIMS) in July 2016, automated Epic reports were generated to provide population-level audits.
RESULTS: After initiation of BBTV and the addition of Epic AIMS, compliance with obtaining three metrics on documentation of patient identification (two electronic signatures, start and stop times of transfusion, and blood volume transfused) was improved during a one-year period to > 96%. Pre-Epic audits had shown a mean compliance of only 86%, mainly reflecting a lack of paper blood component requisitions.
CONCLUSION: By implementing BBTV and using a novel intraoperative documentation process within the Epic AIMS, a safer process of blood transfusion in the ORs was initiated and documentation improved.
Copyright © 2018 The Joint Commission. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2018        PMID: 30389466     DOI: 10.1016/j.jcjq.2018.08.010

Source DB:  PubMed          Journal:  Jt Comm J Qual Patient Saf        ISSN: 1553-7250


  3 in total

1.  Implementing a New Electronic Health Record System in a University Hospital: The Effect on Reported Medication Errors.

Authors:  Carita Lindén-Lahti; Sanna-Maria Kivivuori; Lasse Lehtonen; Lotta Schepel
Journal:  Healthcare (Basel)       Date:  2022-05-31

2.  Nurses' hemovigilance knowledge and performance after teach-back, concept map, and lecture: A quasi-experimental study.

Authors:  Daryadokht Masror Roudsari; Shahoo Feizi; Mahtab Maghsudlu
Journal:  Heliyon       Date:  2021-01-15

3.  Electronic transfusion consent and blood delivering pattern improve the management of blood bank in China.

Authors:  Luxi Jiang; Guobing Zhang; Ke Hao; Weiling Xiang; Qin Zhang; Yiwei Xie; Zhen Wang; Bingyu Chen; Yaoqiang Du
Journal:  BMC Health Serv Res       Date:  2022-04-26       Impact factor: 2.908

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.