| Literature DB >> 30386520 |
Andre-Luiz-Ferreira Costa1, Bruna-Viana Barbosa2, João-Pedro Perez-Gomes3, Alison-Jhisel-Mansmith Calle1, Mauro-Pedrine Santamaria2, Sérgio-Lúcio-Pereira-de Castro Lopes2.
Abstract
BACKGROUND: To analyze the influence of voxel size and exposure time on the accuracy of linear measurements of the condyle.Entities:
Year: 2018 PMID: 30386520 PMCID: PMC6203913 DOI: 10.4317/jced.54500
Source DB: PubMed Journal: J Clin Exp Dent ISSN: 1989-5488
Figure 1A) Identified macerated porcine hemi-mandible with thermo-heated godiva base for stabilization on the I-CAT Next Generation brand scanner. B) Marking points using heated gutta-percha measuring 0.2 mm of diameter in the macerated porcine hemi-mandible´s condyle. Each gutta-percha point represents the most prominent area of the condyle´s medial and lateral poles and anterior and posterior strands. C) Sample positioned and stabilized on a flat support on the I-CAT Next Generation scanner. D) Three-dimensional model generated in multiplanar reconstruction windows (MPR), in which bone tissue protocols were applied. All images were exported in Digital Imaging and Communications in Medicine format to OnDemand3D software (Cybermed, Tustin, CA, USA).
Distribution of protocols according to voxel size, time scan, kilovolt peak and milliamps x seconds. mm – millimeters; s – seconds.
Descriptive statistics of difference between time of the measurement in LM and AP variables. N – Sample size; S.D. – Standard deviation.
Summaries measures between the two repetitions in Latero-Medial variable and result of the comparison between each protocol by rank transformation.
Summaries measures between the two repetitions in Antero-Posterior variable and result of the comparison between each protocol by rank transformation.
Figure 2A) Average and 95% confidence interval of ranks in each protocol considering Latero-Medial measure. P1 – voxel size 0.125 mm with time scan 26.9 seconds; P2 – voxel size 0.20 mm with time scan 14.7 seconds; P3 – voxel size 0.20 mm with time scan 26.9 seconds; P4 – voxel size 0.25 mm with time scan 14.7 seconds; P5 – voxel size 0.25 mm with time scan 26.9 seconds; P6 – voxel size 0.30 mm with time scan 4.8 seconds; P7 – voxel size 0.30 mm with time scan 8.9 seconds; P8 – voxel size 0.40 mm with time scan 4.8 seconds; P9 – voxel size 0.40 mm with time scan 8.9 seconds. B) Average and 95% confidence interval of ranks in each protocol considering Antero-Posterior measure. P1 – voxel size 0.125 mm with time scan 26.9 seconds; P2 – voxel size 0.20 mm with time scan 14.7 seconds; P3 – voxel size 0.20 mm with time scan 26.9 seconds; P4 – voxel size 0.25 mm with time scan 14.7 seconds; P5 – voxel size 0.25 mm with time scan 26.9 seconds; P6 – voxel size 0.30 mm with time scan 4.8 seconds; P7 – voxel size 0.30 mm with time scan 8.9 seconds; P8 – voxel size 0.40 mm with time scan 4.8 seconds; P9 – voxel size 0.40 mm with time scan 8.9 seconds.