Literature DB >> 30381230

Simultaneous determination of aminoglycosides and colistins in food.

G Saluti1, I Diamanti1, D Giusepponi1, L Pucciarini2, R Rossi1, S Moretti1, R Sardella2, R Galarini3.   

Abstract

A novel method for the simultaneous identification and quantification of twelve aminoglycosides (AGs) and two colistins in meat and bovine milk has been developed. The analysis was carried out using liquid chromatography coupled to quadrupole-Orbitrap mass spectrometry (LC-Q-Orbitrap). Among the HILIC (Hydrophilic Interaction Liquid Chromatography) stationary phases tested, the bare silica Poroshell 120 provided the best results. The samples were extracted with an aqueous solution followed by an SPE clean up based on the weak cation exchange mechanism. The validation study was performed carrying out 72 experiments per matrix at six different concentrations in a range encompassing the Maximum Residue Limits. The recoveries were from 72 to 87% in meat (except colistins) and from 82 to 96% in milk. Repeatabilities and intra-lab reproducibilities were lower than 10 and 15%, respectively. Limits of detection were lower than or equal to 33 µg kg-1. Finally, test materials containing AGs prepared for interlaboratory studies were successfully analysed.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aminoglycosides; Colistins; Liquid chromatography high-resolution tandem mass spectrometry; Method validation; Milk; Muscle

Mesh:

Substances:

Year:  2018        PMID: 30381230     DOI: 10.1016/j.foodchem.2018.05.113

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  3 in total

1.  Determination of Polypeptide Antibiotic Residues in Food of Animal Origin by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Tomasz Bladek; Iwona Szymanek-Bany; Andrzej Posyniak
Journal:  Molecules       Date:  2020-07-17       Impact factor: 4.411

Review 2.  Electrochemical Immunosensors for Antibiotic Detection.

Authors:  Aleksandra Pollap; Jolanta Kochana
Journal:  Biosensors (Basel)       Date:  2019-05-01

3.  Determination of Colistin B in Chicken Muscle and Egg Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Harsh Kumar; Dinesh Kumar; Eugenie Nepovimova; Dasharath Oulkar; Anil Kumar; Ramiz Mohammad Rafi Azad; Subodh Kumar Budakoti; Navneet Kumar Upadhyay; Rachna Verma; Kamil Kuča
Journal:  Int J Environ Res Public Health       Date:  2021-03-06       Impact factor: 3.390

  3 in total