PURPOSE: Low-porosity endovascular stents, known as flow diverters (FDs), have been proposed as an effective and minimally invasive treatment for sidewall intracranial aneurysms (IAs). Although it has been reported that the efficacy of a FD is substantially influenced by its porosity, clinical doctors would clearly prefer to do their interventions optimally based on refined quantitative data. This study focuses on the association between the porosity configurations and the FD efficacy, in order to provide practical data to help the clinical doctors optimize the interventions.
METHOD: Numerical simulations in fluid dynamics were performed using four patient-specific IA geometries, pulsatile velocity profiles and braided fully resolved FDs. The variation of velocity and wall shear stress within the IAs, were investigated in this study. Lattice Boltzmann method (LBM) was used to solve the main challenge centered on the diversity of spatial scales since the typical diameter of struts of FDs is only 25μm while the artery normally can be larger by a hundred times.
RESULTS: Numerical simulations revealed that the blood flow within IA sac was substantially reduced when the porosity is less than 86%. In particular, the flow condition within each IA sac is favorite to initialize thrombus formation when porosity is less than 70%.
CONCLUSION: Our study suggests the existence of a porosity threshold below which the efficacy of a FD will be sufficient for the patients to initialize the thrombus formation. Therefore, by estimating the porosity of FD on patient-specific information, it may be potentially to predict whether or the blood flow condition will successfully become prothrombotic after the FD intervention.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Blood flow simulation; Fully-resolved flow diverter stent; Intracranial aneurysm; Lattice Boltzmann method; Patient-specific geometry; Thrombosis; Wall shear stress

Mesh:

Year:  2018        PMID: 30381156     DOI: 10.1016/j.jbiomech.2018.10.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  In-silico trial of intracranial flow diverters replicates and expands insights from conventional clinical trials.

Authors:  Ali Sarrami-Foroushani; Toni Lassila; Michael MacRaild; Joshua Asquith; Kit C B Roes; James V Byrne; Alejandro F Frangi
Journal:  Nat Commun       Date:  2021-06-23       Impact factor: 14.919

2.  Adaptive wireless millirobotic locomotion into distal vasculature.

Authors:  Tianlu Wang; Halim Ugurlu; Yingbo Yan; Mingtong Li; Meng Li; Anna-Maria Wild; Erdost Yildiz; Martina Schneider; Devin Sheehan; Wenqi Hu; Metin Sitti
Journal:  Nat Commun       Date:  2022-08-01       Impact factor: 17.694

Review 3.  Mechanism of Action and Biology of Flow Diverters in the Treatment of Intracranial Aneurysms.

Authors:  Krishnan Ravindran; Amanda M Casabella; Juan Cebral; Waleed Brinjikji; David F Kallmes; Ram Kadirvel
Journal:  Neurosurgery       Date:  2020-01-01       Impact factor: 4.654

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.