Incorrect frozen elephant trunk deployment into the false lumen of a patient with complicated type B acute dissection.

Masahiko Fujii1, Hiroyuki Watanabe1, Masayoshi Otsu1, Yuta Sugahara1.   

Abstract

Total arch replacement with frozen elephant trunk (FET) is used for type B acute aortic dissection with insufficient proximal landing zone. Herein, we report incorrect deployment of FET into the false lumen. A 45-year-old man underwent femorofemoral bypass for complicated type B acute aortic dissection. However, chest pain recurred 4 days postoperatively, and an oozing rupture of the dissecting descending aorta was diagnosed. As preoperative computed tomography showed insufficient proximal landing zone and separate chronic aortic dissection of the proximal arch, total arch replacement with FET was performed. Progressive lactic acidosis occurred on postoperative day 2, and computed tomography showed incorrect deployment of the FET into the false lumen, causing true lumen stenosis and intestinal ischaemia. Despite extensive enterectomy and abdominal aorta fenestration for the improvement of true lumen perfusion, the patient died of multiorgan failure on postoperative day 7. Care is required to avoid incorrect deployment of FET when there is a large entry in the proximal descending aorta.
© The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic arch; Aortic dissection; Frozen elephant trunk

Year:  2019        PMID: 30380033     DOI: 10.1093/ejcts/ezy357

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  2 in total

1.  Case of rapid aortic remodeling after thoracic endovascular aortic repair for retrograde type A aortic dissection.

Authors:  Yuta Kikuchi; Masahiro Tsutsui; Kohei Ishido; Masahiko Narita; Ryohei Ushioda; Tomonori Shirasaka; Natsuya Ishikawa; Hiroyuki Kamiya
Journal:  J Surg Case Rep       Date:  2022-03-01

2.  Rapid false lumen dilation and pseudocoarctation due to inadvertent preferential false lumen perfusion using the frozen elephant trunk technique in a chronic residual aortic dissection.

Authors:  Jelle Fleerakkers; Uday Sonker; Robin H Heijmen
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-02-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.