Literature DB >> 30371922

Revision Total Hip Arthroplasty for Paprosky Type III Acetabular Defect With Structural Allograft and Tantalum Trabecular Metal Acetabular Cup.

Chih-Hsiang Chang, Chih-Chien Hu, Chun-Chieh Chen, John Mahajan, Yuhan Chang, Hsin-Nung Shih, Young-Min Kwon.   

Abstract

There are several surgical options for addressing Paprosky type III acetabular defects during revision total hip arthroplasty. In physiologically young and active patients, using structural bone graft to restore bone defects and provide adequate initial support for the revision acetabular component is one such option. This study reports the mid-term results of using a structural allograft accompanied by a trabecular metal-coated hemispherical cup for Paprosky type III defects. A retrospective analysis was performed of the data collected for 20 consecutive hips in 20 patients (mean age, 56.2 years; range, 43-68 years) with minimum 3-year follow-up (mean, 5.4 years; range, 3.3-10.3 years) who had a structural allograft accompanied by a trabecular metal-coated hemispherical cup for Paprosky type III defects. Only 1 hip had cup migration, which was less than 3 mm in vertical and less than 5° in inclination and recognized as loosening without symptoms. All grafts showed good incorporation with trabecular bridging over the graft and host bone. The mean modified Harris hip score showed significant improvement, from 29.7 (range, 11-52) preoperatively to 84.1 (range, 77-91) at the latest follow-up (P<.05). The use of a structural allograft combined with a tantalum trabecular metal acetabular cup in acetabular revision for Paprosky type III defects had a satisfactory mid-term clinical result. This is a viable option for patients with large acetabular shelf defects. [Orthopedics. 2018; 41(6):e861-e867.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30371922     DOI: 10.3928/01477447-20181023-02

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  3D Printed Acetabular Components for Complex Revision Arthroplasty.

Authors:  Angela Yao; Daniel Mark George; Vijai Ranawat; Chris John Wilson
Journal:  Indian J Orthop       Date:  2021-01-03       Impact factor: 1.251

2.  Customised three-dimensional printed revision acetabular implant for large defect after failed triflange revision cup.

Authors:  Stefano Zanasi; Hassan Zmerly
Journal:  BMJ Case Rep       Date:  2020-05-25

3.  Acetabular Revision Surgery with Tantalum Trabecular Metal Acetabular Cup for Failed Acetabular Cage Reconstruction with Bone Allografts: A Retrospective Study with Mid- to Long-Term Follow-Up.

Authors:  Chen-Heng Hsu; Chih-Chien Hu; Chih-Hsiang Chang; Yu-Han Chang; Hsin-Nung Shih; Chun-Chieh Chen
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

Review 4.  Clinical and radiological outcomes of jumbo cup in revision total hip arthroplasty: A systematic review.

Authors:  Qiuyuan Wang; Qi Wang; Pei Liu; Juncheng Ge; Qidong Zhang; Wanshou Guo; Weiguo Wang
Journal:  Front Surg       Date:  2022-10-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.