Literature DB >> 30371610

Virtual Monoenergetic Images for Diagnostic Assessment of Hypodense Lesions Within the Liver: Semiautomatic Estimation of Window Settings Using Linear Models.

Nils Große Hokamp, Verena C Obmann, Rivka Kessner, Robert C Gilkeson, Amit Gupta, Thorsten Persigehl1, Stefan Haneder1, Nikhil Ramaiya.   

Abstract

OBJECTIVE: The aim of the study was to establish the reference window settings for display of virtual monoenergetic images (VMIs) from spectral detector computed tomography when assessing hypodense liver lesions.
METHODS: In patients with cysts (n = 24) or metastases (n = 26), objective (HU, signal-to-noise ratio [SNR]) and subjective (overall image quality, lesion conspicuity and noise) were assessed. Furthermore, 2 readers determined optimal window center/width (C/W) for conventional images (CIs) and VMIs of 40 to 120 keV. Center/width were modeled against HUliv with and without respect to the keV level (models A and B).
RESULTS: Attenuation and SNR were significantly higher in low-keV VMIs and improved overall image quality and lesion conspicuity (P ≤ 0.05). Model B provided valid estimations of C/W, whereas model A was slightly less accurate.
CONCLUSIONS: The increase in attenuation and SNR on low-keV VMIs requires adjustment of C/W, and they can be estimated in dependency of HUliv using linear models. Reference values for standard display of VMIs of 40 to 120 keV are reported.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30371610     DOI: 10.1097/RCT.0000000000000794

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

Review 1.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

2.  Optimal Conspicuity of Liver Metastases in Virtual Monochromatic Imaging Reconstructions on a Novel Photon-Counting Detector CT-Effect of keV Settings and BMI.

Authors:  Stefanie Bette; Josua A Decker; Franziska M Braun; Judith Becker; Mark Haerting; Thomas Haeckel; Michael Gebhard; Franka Risch; Piotr Woźnicki; Christian Scheurig-Muenkler; Thomas J Kroencke; Florian Schwarz
Journal:  Diagnostics (Basel)       Date:  2022-05-14

3.  Generally applicable window settings of low-keV virtual monoenergetic reconstructions in dual-layer CT-angiography of the head and neck.

Authors:  David Zopfs; Simon Lennartz; Nuran Abdullayev; Thorsten Lichtenstein; Kai Roman Laukamp; Robert Peter Reimer; Christoph Kabbasch; Jan Borggrefe; Marc Schlamann; Victor Neuhaus; Nils Große Hokamp
Journal:  Quant Imaging Med Surg       Date:  2021-08

4.  Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions.

Authors:  R P Reimer; N Große Hokamp; A Fehrmann Efferoth; A Krauskopf; D Zopfs; J R Kröger; T Persigehl; D Maintz; A C Bunck
Journal:  Eur Radiol       Date:  2020-11-12       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.