Patient and operating room staff radiation dose during fenestrated/branched endovascular aneurysm repair using premanufactured devices.

Melissa L Kirkwood1, Khalil Chamseddin2, Gary M Arbique3, Jeffrey B Guild3, David Timaran2, Jon A Anderson3, Carlos Timaran2.   

Abstract

INTRODUCTION: Fenestrated endovascular aneurysm repair (FEVAR) is the highest radiation dose procedure performed by vascular surgeons. We sought to characterize the radiation dose to patients and staff during FEVAR procedures with different premanufactured devices.
METHODS: A single-center prospective study of FEVARs was performed over 24 months. Three FEVAR devices were included: off-the-shelf (OTS; t-Branch, p-Branch), Zenith Fenestrated (ZFen), and investigational custom-made devices (CMDs). Radiation doses to the surgeon, trainee, anesthesiologist, and scrub/circulating nurses were measured using a personal dosimetry system (DoseAware, Philips Healthcare, Amsterdam, The Netherlands). Procedure type, patient body mass index (BMI), reference air kerma (RAK), and kerma area product (KAP) were recorded. RAK and KAP were corrected for BMI based on an exponential fit of fluoroscopy dose rate and the dose per radiographic frame. Operator dose was corrected for BMI by the ratio of corrected to actual KAP. A one-sided Wilcox rank-sum test was used to compare personnel radiation doses, RAKs, and KAPs between procedure types. Statistical significance was set at P ≤ .05.
RESULTS: There were 80 FEVARs performed by a single surgeon on a Philips Allura XperFD20 fluoroscopy system equipped with Clarity technology. Average BMI was 27 kg/m2. Sixty CMDs (36 four-, 21 three-, and 3 two-vessel fenestrations), 11 ZFens (8 three- and 3 two-vessel fenestrations), and 9 OTS devices (4 p-Branch, 5 t-Branch) were included. ZFens had significantly lower patient (1800 mGy vs 2950 mGy; P = .004), operator (120 μSv vs 370 μSv; P = .004), assistant (60 μSv vs 210 μSv; P = .003), circulator (10 μSv vs 30 μSv; P = .049), and scrub nurse dose (10 μSv vs 40 μSv; P = .02) compared with CMDs. OTS devices had significantly lower operator (220 μSv vs 370 μSv; P = .04), assistant (110 μSv vs 210 μSv; P = .02), and circulator doses (4 μSv vs 30 μSv; P = .001) compared with CMDs. Four-vessel fenestrated devices had significantly higher patient dose (3020 mGy) compared with three-vessel FEVARs (2670 mGy; P = .03) and two-vessel FEVARs (1600 mGy; P = .0007), and significantly higher operator dose (440 μSv) compared with three-vessel FEVARs (170 μSv; P = .0005). Patient dose was lowest with ZFens. Operating room personnel dose was lower with ZFens and OTS devices compared with CMDs. Four-vessel fenestrations required significantly more radiation compared with those involving three-vessel fenestrations; however, the dose increase was only 12% and should not preclude operators from extending coverage, if anatomically required.
CONCLUSIONS: Overall, patient and personnel radiation doses during FEVAR with all devices were within acceptable limits and lower in our series than previously reported.
Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  FEVAR; Fenestrated endovascular aneurysm repair; Fluoroscopically guided interventions; Occupational radiation dose; Radiation dose

Mesh:

Year:  2018        PMID: 30369410     DOI: 10.1016/j.jvs.2018.02.031

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

1.  Gutter Characteristics and Stent Compression of Self-Expanding vs Balloon-Expandable Chimney Grafts in Juxtarenal Aneurysm Models.

Authors:  Jorn P Meekel; Theodorus G van Schaik; Rutger J Lely; Gerie Groot; Bram B van der Meijs; Willem Wisselink; Jan D Blankensteijn; Kak K Yeung
Journal:  J Endovasc Ther       Date:  2020-04-21       Impact factor: 3.487

2.  Safety and Feasibility of Performing Fenestrated Endovascular Abdominal Aneurysm Repair Using a Portable C-arm Without Fusion Technology: A Single-Center Experience.

Authors:  Amandeep Juneja; Saqib Zia; Marco H Ayad; Kuldeep Singh; Jonathan Dietch; Jonathan Schor
Journal:  Cureus       Date:  2020-04-20

3.  Hybrid operating room applications in the increasingly complex endovascular era: the trump card of modern vascular surgery.

Authors:  Davide Esposito; Francesco Gonfiantini; Aaron Thomas Fargion; Walter Dorigo; Flavio Villani; Rossella Di Domenico; Sara Speziali; Carlo Pratesi
Journal:  Ann Surg Treat Res       Date:  2020-12-30       Impact factor: 1.859

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.