Literature DB >> 30357464

Arterial Phase CTA Replacement by a Virtual Arterial Phase Reconstruction from a Venous Phase CTA: Preliminary Results Using Detector-Based Spectral CT.

Anish A Patel1, Patrick D Sutphin2, Yin Xi2, Suhny Abbara2, Sanjeeva P Kalva2.   

Abstract

OBJECTIVE: To assess the feasibility of creating virtual monoenergetic arterial images from venous phase CTA obtained on a detector-based spectral CT scanner and quantitatively compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios of the major arteries to those on polyenergetic true arterial phase images.
METHODS: In this retrospective study, 23 patients (15 men and 8 women, median age 68 years) who underwent triple-phase CTA on a spectral CT scanner for aortic endograft surveillance were included. The venous phase CTA of each study was reconstructed to generate virtual monoenergetic images at various keV, which were compared to true arterial phase CTA images. SNR and CNR of the aortoiliac arteries were evaluated by testing the differences in means and non-inferiority of virtual arterial images to true arterial images. Effective radiation dose was calculated for standard triple-phase studies in comparison with dual-phase and single-phase spectral CT examinations.
RESULTS: Virtual monoenergetic images demonstrated non-inferior (P < 0.05) arterial SNR and CNR compared to true arterial images at 40 keV for all arteries, at 45-50 keV for the thoracic and suprarenal aorta, and at 45-55 keV for the infrarenal aorta and iliac arteries. Significantly higher (P < 0.05) arterial attenuation was obtained at 40 keV for the aortoiliac arteries. Mean effective dose for conventional triple-phase studies was 32.5 mSv in comparison with 21.3 mSv for dual-phase non-contrast/venous scans and 11.3 mSv for single-phase venous scans.
CONCLUSIONS: Detector-based spectral CT enables creation of virtual monoenergetic arterial images from venous phase CTA with equivalent and in some cases significantly higher SNR/CNR of major arteries compared to images from true arterial phase polyenergetic CTA.

Entities:  

Keywords:  Aorta; CT angiography; Dual-energy CT; Spectral CT

Mesh:

Year:  2018        PMID: 30357464     DOI: 10.1007/s00270-018-2096-8

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

1.  Aortic CT angiography using the double region of interest timing bolus technique: feasibility of 80 kVp scanning in lean patients.

Authors:  Nobuo Tomizawa; Shingo Ito; Tastuya Nakao; Hiroaki Arakawa; Kodai Yamamoto; Shinichi Inoh; Takeshi Nojo; Sunao Nakamura
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-02       Impact factor: 2.357

2.  Dual-Layer Spectral CT of Pancreas Ductal Adenocarcinoma: Can Virtual Monoenergetic Images of the Portal Venous Phase Be an Alternative to the Pancreatic-Phase Scan?

Authors:  Yeo Eun Han; Beom Jin Park; Deuk Jae Sung; Min Ju Kim; Na Yeon Han; Ki Choon Sim; Yongwon Cho; Hayeon Kim
Journal:  J Belg Soc Radiol       Date:  2022-09-22       Impact factor: 1.912

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.