Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation.

Lin Zhang1, Qiang Li1, Chiao-Yin Wang2,3, Po-Hsiang Tsui3,4,5.   

Abstract

Radiofrequency (RF) ablation (RFA) is the most commonly used minimally invasive procedure for thermal ablation of liver tumors. Ultrasound not only provides real-time feedback of the electrode location for RFA guidance but also enables visualization of the tissue temperature. Changes in backscattered energy (CBE) have been widely applied to ultrasound temperature imaging for assessing thermal ablation. Pilot studies have revealed that significant shadowing features appear in CBE imaging and are caused by the electrode and RFA-induced gas bubbles. To resolve this problem, the current study proposed ultrasound single-phase CBE imaging based on positive CBE values. An in vitro model with tissue samples derived from the porcine tenderloin was used to validate the proposed method. During RFA with various electrode lengths, ultrasound scans of tissue samples were obtained using a clinical ultrasound scanner equipped with a convex array transducer of 3 MHz. Raw image data comprising 256 scan lines of backscattered RF signals were acquired for B-mode, conventional CBE, and single-phase CBE imaging by using the proposed algorithmic scheme. The ablation sizes estimated using CBE imaging and gross examinations were compared to calculate the correlation coefficient. The experimental results indicated that single-phase CBE imaging largely suppressed artificial CBE information in the shadowed region. Moreover, compared with conventional CBE imaging, single-phase CBE imaging provided a more accurate estimation of ablation sizes (the correlation coefficient was higher than 0.8).

Entities:  

Keywords:  Ultrasound; changes in the backscattered energy; radiofrequency ablation

Mesh:

Year:  2018        PMID: 30354749     DOI: 10.1080/02656736.2018.1512160

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  4 in total

1.  Comparison of ultrasound guided versus CT guided radiofrequency ablation on liver function, serum PIVKA-II, AFP levels and recurrence in patients with primary hepatocellular carcinoma.

Authors:  Zusheng Yu; Guowei Li; Nianyong Yuan; Wei Ding
Journal:  Am J Transl Res       Date:  2021-06-15       Impact factor: 4.060

2.  High Contrast Ultrasonic Method With Multi-Spatiotemporal Compounding for Monitoring Catheter-Based Ultrasound Thermal Therapy: Development and Ex Vivo Evaluations.

Authors:  Diya Wang; Matthew S Adams; Peter D Jones; Dong Liu; Everette C Burdette; Chris J Diederich
Journal:  IEEE Trans Biomed Eng       Date:  2021-09-20       Impact factor: 4.756

3.  Deep heat therapy system with resonant cavity applicator for articular cartilage in knee osteoarthritis.

Authors:  Yasuhiro Shindo; Kenji Takahashi; Futoshi Ikuta; Yuya Iseki; Kazuhiro Harada; Kazuo Kato
Journal:  J Phys Ther Sci       Date:  2020-12-11

4.  Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation of the liver tumor: A preliminary clinical validation.

Authors:  Chiao-Yin Wang; Zhuhuang Zhou; Yu-Hsuan Chang; Ming-Chih Ho; Chiu-Min Lu; Chih-Horng Wu; Po-Hsiang Tsui
Journal:  Front Oncol       Date:  2022-07-22       Impact factor: 5.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.