Literature DB >> 30350124

Potentials and pitfalls of gold-silica nanoshell as the exogenous contrast agent for optical diagnosis of cancers: a numerical parametric study.

Xiao Xu1.   

Abstract

For nanoshell-assisted optical detection of cancers, gold shell, silica core (gold-silica) nanoshells are engineered to be the exogenous contrast agent. This work has performed systematic numerical parametric study to investigate the nonlinear dependences of the hemisphere diffuse reflectance on gold-silica nanoshells, laser irradiance, and hosting biology tissue. Planar phantom based tissue models have been constructed as platforms for study. The radiant transport equation (RTE) has been applied to mathematically describe the interactions among laser lights, hosting tissues, and hosted nanoshells. The diffuse reflectance signal under various combinations of parametric conditions has been computed and analyzed. Parametric parameters whose effects on the diffuse reflectance signal have been investigated are: (1) optical properties of a nanoshell generic, (2) nanoshell volume fraction, which is an indicator of nanoshell accumulation in the target tissue site, (3) the width of irradiating laser beam, and (4) thickness of the tissue slab. Seven nanoshell generics have been tested as the exogenous contrast agent including the R[50, 10] (radius of silica core is 50 nm and thickness of gold shell is 10 nm), R[55, 25], R[40, 15], R[40, 40], R[104, 23], R[75, 40] and R[154, 24] nanoshells. It has been found the R[55, 25] nanoshell works best as the exogenous contrast agent, the R[75, 40] and R[104, 23] nanoshells show good potentials as well while the R[50, 10] and R[40, 15] nanoshells should be avoided for diagnostic usage. The practice of neglecting the absorption characteristic of the exogenous contrast agent, which is quite common among the bio-nano community, has been proven to end up with an over-prediction of the effectiveness of the exogenous contrast agent. Such practice therefore is not well justified and should be avoided in future research. Interactions among laser lights, the tissue and nanoshells are highly nonlinear, demonstrated by that nanoshell generics with totally different optical properties might have similar effects on the diffuse reflectance signal and vice versa. Prior to any bench experiment, preliminary numerical investigation as this work has showcased is highly recommended.

Entities:  

Keywords:  Cancer detection; Gold-silica nanoshell; Lasers; Optical imaging

Mesh:

Substances:

Year:  2018        PMID: 30350124     DOI: 10.1007/s10103-018-2639-x

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  37 in total

1.  Quantitative near-infrared spectroscopy of cervical dysplasia in vivo.

Authors:  R Hornung; T H Pham; K A Keefe; M W Berns; Y Tadir; B J Tromberg
Journal:  Hum Reprod       Date:  1999-11       Impact factor: 6.918

2.  The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy.

Authors:  R M Doornbos; R Lang; M C Aalders; F W Cross; H J Sterenborg
Journal:  Phys Med Biol       Date:  1999-04       Impact factor: 3.609

3.  Realistic three-dimensional epithelial tissue phantoms for biomedical optics.

Authors:  Konstantin Sokolov; Javier Galvan; Alexey Myakov; Alicia Lacy; Rueben Lotan; Rebecca Richards-Kortum
Journal:  J Biomed Opt       Date:  2002-01       Impact factor: 3.170

4.  In vivo optical characterization of human tissues from 610 to 1010 nm by time-resolved reflectance spectroscopy.

Authors:  A Torricelli; A Pifferi; P Taroni; E Giambattistelli; R Cubeddu
Journal:  Phys Med Biol       Date:  2001-08       Impact factor: 3.609

Review 5.  The enhanced permeability and retention (EPR) effect in tumor vasculature: the key role of tumor-selective macromolecular drug targeting.

Authors:  H Maeda
Journal:  Adv Enzyme Regul       Date:  2001

6.  Design of a high-numerical-aperture miniature microscope objective for an endoscopic fiber confocal reflectance microscope.

Authors:  Chen Liang; Kung-Bin Sung; Rebecca R Richards-Kortum; Michael R Descour
Journal:  Appl Opt       Date:  2002-08-01       Impact factor: 1.980

7.  A phantom with tissue-like optical properties in the visible and near infrared for use in photomedicine.

Authors:  M Lualdi; A Colombo; B Farina; S Tomatis; R Marchesini
Journal:  Lasers Surg Med       Date:  2001       Impact factor: 4.025

8.  Diagnosis of superficial esophageal cancer and dysplasia using endoscopic screening with a 2% lugol dye solution in patients with head and neck cancer.

Authors:  A J Tincani; N Brandalise; A Altemani; R C Scanavini; J B Valério; H T Lage; G Molina; A S Martins
Journal:  Head Neck       Date:  2000-03       Impact factor: 3.147

Review 9.  Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review.

Authors:  H Maeda; J Wu; T Sawa; Y Matsumura; K Hori
Journal:  J Control Release       Date:  2000-03-01       Impact factor: 9.776

10.  Reliability of toluidine blue application in the detection of oral epithelial dysplasia and in situ and invasive squamous cell carcinomas.

Authors:  M A Onofre; M R Sposto; C M Navarro
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2001-05
View more
  1 in total

1.  A prospective randomized controlled trial comparing the effect and safety of Piranha and VersaCut morcellation devices in transurethral holmium laser enucleation of the prostate.

Authors:  Yanbo Chen; Huan Xu; Dajun Gao; Meng Gu; Chong Liu; Ming Zhan; Zhikang Cai; Qi Chen; Zhong Wang
Journal:  Int Urol Nephrol       Date:  2022-05-21       Impact factor: 2.266

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.