Literature DB >> 30346267

Systematic Screening Using Luminex for De Novo C3d Fixing of Class II Donor-Specific Antibodies Is Correlated With Luminex Mean Fluorescence Intensity in Renal Transplant Patients.

Morgane Villemaire1, Thomas Jouve, Anne Bourdin, Bénédicte Janbon, Nicole Pinel, Rachel Tetaz, Nicolas Terrier, Lionel Rostaing, Dominique Masson, Paolo Malvezzi.   

Abstract

OBJECTIVES: Chronic antibody-mediated rejection is the main cause of late kidney graft loss. The presence of donor-specific antibodies in the serum is the main criterion for this diagnosis. Single antigen Luminex assays can identify donor-specific antibodies, and semiquantitative estimates of antibodies can be assessed using mean fluorescence intensity. Recent data have shown that patients whose donor-specific antibodies fix C3d have worse clinical outcomes, implying that C3d-specific Luminex assays may provide useful prognostic data.
MATERIALS AND METHODS: We compared C3d donor-specific antibodies with standard immunoglobulin G donor-specific antibody mean fluorescence intensities in a cohort of patients with de novo class II donor-specific antibodies and analyzed subsequent graft survival. The included kidney graft recipients received transplants between 2005 and 2015 and had developed de novo class II donor-specific antibodies. Serum was tested using the standard single antigen Luminex technique and the C3d-fixing antibody-detection system (Immucor, Herentals, Belgium).
RESULTS: In our patient cohort, 41/924 patients (4.4%) developed class II donor-specific antibodies, and 65 serum samples were analyzed (at baseline and follow-up). Among these samples, 43 (66%) were negative for C3d donor-specific antibodies. A mean fluorescence intensity threshold of 9000 in the single antigen Luminex assay discerned all negative (from positive) C3d donor-specific antibodies, even when all single-bead results were taken into account. Sixteen patients (39%) had poor outcomes (ie, either creatinine levels had doubled or they had lost their graft) over the median follow-up of 5 years. C3d results were significantly associated with graft survival (P = .04). We found a strong correlation between C3d-fixing antibody positivity and mean fluorescence intensity strength in the setting of de novo class II donor-specific antibodies.
CONCLUSIONS: These results further reinforce the paradigm that the higher the mean fluorescence intensity, the more complement activation occurs. Routine C3d testing is thus unnecessary in this setting.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30346267     DOI: 10.6002/ect.2018.0063

Source DB:  PubMed          Journal:  Exp Clin Transplant        ISSN: 1304-0855            Impact factor:   0.945


  1 in total

1.  Marginal Impact of Tocilizumab Monotherapy on Anti-HLA Alloantibodies in Highly Sensitized Kidney Transplant Candidates.

Authors:  Mélanie Daligault; Béatrice Bardy; Johan Noble; Anne Bourdin; Dominique Masson; Hamza Naciri Bennani; Mathilde Bugnazet; Paolo Malvezzi; Lionel Rostaing; Thomas Jouve
Journal:  Transplant Direct       Date:  2021-04-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.