Literature DB >> 30345060

Iron Oxide Nanowire-Based Filter for Inactivation of Airborne Bacteria.

Dawei Wang1, Bin Zhu2, Xiang He1, Zan Zhu1, Grant Hutchins1, Ping Xu2, Wei-Ning Wang1.   

Abstract

Heating, ventilation, and air conditioning (HVAC) systems are among the most common methods to improve indoor air quality. However, after long-term operation, the HVAC filter can result in a proliferation of bacteria, which may release into the filtered air subsequently. This issue can be addressed by designing antibacterial filters. In this study, we report an iron oxide nanowires-based filter fabricated from commercially available iron mesh through a thermal treatment. At optimal conditions, the filter demonstrated a log inactivation efficiency of > 7 within 10 seconds towards S. epidermidis (Gram-positive), a common bacterial species of indoor bioaerosol. 52 % of bioaerosol cells can be captured by a single filter, which can be further improved to 98.7 % by connecting five filters in-tandem. The capture and inactivation capacity of the reported filter did not degrade over long-term use. The inactivation of bacteria is attributed to the synergic effects of the hydroxyl radicals, electroporation, and Joule heating, which disrupted the cell wall and nucleoid of S. epidermidis, as verified by the model simulations, fluorescence microscopy, electron microscopy, and infrared spectroscopy. The relative humidity plays an important role in the inactivation process. The filter also exhibited a satisfactory inactivation efficiency towards E. coli (Gram-negative). The robust synthesis, low cost, and satisfactory inactivation performance towards both Gram-positive and Gram-negative bacteria make the filter demonstrated here suitable to be assembled into HVAC filters as an antibacterial layer for efficient control of indoor bioaerosols.

Entities:  

Keywords:  Bioaerosols; Electroporation; Hydroxyl radicals; Iron oxide nanowires; Joule heating

Year:  2018        PMID: 30345060      PMCID: PMC6193566          DOI: 10.1039/C8EN00133B

Source DB:  PubMed          Journal:  Environ Sci Nano


  29 in total

1.  Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

Authors:  M Möritz; H Peters; B Nipko; H Rüden
Journal:  Int J Hyg Environ Health       Date:  2001-07       Impact factor: 5.840

2.  Highly active heterogeneous Fenton catalyst using iron oxide nanoparticles immobilized in alumina coated mesoporous silica.

Authors:  Hacgyu Lim; Jinwoo Lee; Sunmi Jin; Jaeyun Kim; Jeyong Yoon; Taeghwan Hyeon
Journal:  Chem Commun (Camb)       Date:  2005-12-12       Impact factor: 6.222

3.  Rapid inactivation of biological species in the air using atmospheric pressure nonthermal plasma.

Authors:  Yongdong Liang; Yan Wu; Ke Sun; Qi Chen; Fangxia Shen; Jue Zhang; Maosheng Yao; Tong Zhu; Jing Fang
Journal:  Environ Sci Technol       Date:  2012-03-08       Impact factor: 9.028

4.  Inactivation of microorganisms using electrostatic fields.

Authors:  Maosheng Yao; Gediminas Mainelis; Hey Reoun An
Journal:  Environ Sci Technol       Date:  2005-05-01       Impact factor: 9.028

5.  Fe@Fe2O3 core-shell nanowires enhanced Fenton oxidation by accelerating the Fe(III)/Fe(II) cycles.

Authors:  Jingu Shi; Zhihui Ai; Lizhi Zhang
Journal:  Water Res       Date:  2014-04-18       Impact factor: 11.236

6.  Classification and identification of bacteria by Fourier-transform infrared spectroscopy.

Authors:  D Helm; H Labischinski; G Schallehn; D Naumann
Journal:  J Gen Microbiol       Date:  1991-01

7.  The history of ultraviolet germicidal irradiation for air disinfection.

Authors:  Nicholas G Reed
Journal:  Public Health Rep       Date:  2010 Jan-Feb       Impact factor: 2.792

8.  Development of a photocatalytic filter to control indoor air quality.

Authors:  Barbara Del Curto; Paolo Tarsini; Alberto Cigada
Journal:  J Appl Biomater Funct Mater       Date:  2016-11-02       Impact factor: 2.604

9.  Visible-light-driven photocatalytic inactivation of MS2 by metal-free g-C3N4: Virucidal performance and mechanism.

Authors:  Yi Li; Chi Zhang; Danmeng Shuai; Saraschandra Naraginti; Dawei Wang; Wenlong Zhang
Journal:  Water Res       Date:  2016-10-05       Impact factor: 11.236

10.  Nanowire-Modified Three-Dimensional Electrode Enabling Low-Voltage Electroporation for Water Disinfection.

Authors:  Zheng-Yang Huo; Xing Xie; Tong Yu; Yun Lu; Chao Feng; Hong-Ying Hu
Journal:  Environ Sci Technol       Date:  2016-07-01       Impact factor: 9.028

View more
  3 in total

1.  Microwave-induced release and degradation of airborne endotoxins from Escherichia coli bioaerosol.

Authors:  C Wang; Z W Zhang; H Liu
Journal:  J Hazard Mater       Date:  2018-11-23       Impact factor: 10.588

2.  Triboelectrification induced self-powered microbial disinfection using nanowire-enhanced localized electric field.

Authors:  Zheng-Yang Huo; Young-Jun Kim; In-Yong Suh; Dong-Min Lee; Jeong Hwan Lee; Ye Du; Si Wang; Hong-Joon Yoon; Sang-Woo Kim
Journal:  Nat Commun       Date:  2021-06-17       Impact factor: 14.919

3.  Inactivation of airborne bacteria using different UV sources: Performance modeling, energy utilization, and endotoxin degradation.

Authors:  Can Wang; Siyi Lu; Zhiwei Zhang
Journal:  Sci Total Environ       Date:  2018-11-20       Impact factor: 7.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.