Literature DB >> 30344841

Endotracheal Tube Fixation in Patients With Facial Burns, What Are the Options?

Patrick Assi1, Luis Quiroga1, Kevin Gerold1, Julie Caffrey1.   

Abstract

Entities:  

Keywords:  endotracheal tube fixation; endotracheal tube stabilization; facial burns; intermaxillary fixation screw; securing ET tube

Year:  2018        PMID: 30344841      PMCID: PMC6178206     

Source DB:  PubMed          Journal:  Eplasty        ISSN: 1937-5719


× No keyword cloud information.

DESCRIPTION

A 52-year-old alcoholic woman sustained a 40% total body surface area full-thickness flame burn to her torso, face, neck, and scalp, as well as an inhalational injury. We describe a valid and safe technique to be used for endotracheal (ET) tube fixation using intermaxillary fixation (IMF) in an edentulous patient with facial burns. What are the challenges in ET tube fixation in patients with facial burns? What factors make this described technique an easy and safe method for ET tube fixation in edentulous patients with facial burns? What are the available options described in the literature for ET tube fixation in facial burns? What are the available options in patients with good dentition?

DISCUSSION

Intubated patients with severe head and neck burns are challenging in every aspect, including securing the ET tube in place since dislodgement is a life-threatening complication in the context of inhalational injury. Aggressive wound care to the face and delayed staged surgical interventions for excision and grafting are the standard of care for head and neck deep burns. Securing the ET tube in the regular fashion using cloth tapes or tube holders is not ideal. The straps and tape will only increase the level of injury due to increasing friction and will disrupt the skin grafts. A major factor impacting our choice of fixation method is whether the patient is edentulous or not. We believe that the method of choice for ET tube fixation should be safe, easy to perform, readily available, and reproducible. A 2.0-mm DePuy Synthes IMF screw of 8-mm length was used in our case. It is a fenestrated stainless steel screw with 2 cross-holes. A screwdriver was used to insert the screw in the alveolar process of the maxilla. A 0.4-mm stainless steel wire was used and was guided through the cross-holes to fixate the ET tube. For edentulous patients, fixation of the ET tube using IMF screws has been reported for patients with facial burns or in maxillofacial surgery. Multiple insertion techniques are described.1-3 The use of the IMF screw is associated with good oral hygiene, and no complications were reported in this context. Possible complications that can be predicted are hardware failure, screw site infection, screw loosening, soft tissue irritation, and accidental screw insertion into the maxillary sinus.1,2 It is a fast, minimally invasive method that can be applied safely, and the screws can be removed easily when tracheostomy becomes indicated or extubation is in order. The main contraindications for the IMF screw are any comminuted, unstable, or displaced maxillary or mandibular fractures. An external cranial fixation device was used in this population of patients back in 1978 by Hansen. This method is invasive, and wound care becomes harder compared with our method.4 Other methods previously described include the use of a nasal bridle to secure an ET tube in a child with facial blistering. This method is readily performed, although it might be avoided in specific cases such as ours where minor/major alar cartilages are completely burned, although these are not necessarily considered contraindications for the use of a nasal bridle. Circummandibular, transpalatal, and even transmaxillary wires can also be used for ET fixation at the expense of soft tissue damage and the increased risk of infection with associated poor oral hygiene.5 For patients with good dentition, interdental wire fixation was reported as a valid method where a stainless steel wire was inserted in the interdental spaces and anchoring around 1 or multiple teeth bases. This is the standard method used in our center in patients with good dentition. This method has its challenges and is associated with difficulty with appropriate hygiene and gingival injury. It can cause damage to the base of the teeth and loosen them, especially in the case of poor dentition. Multiple other methods are available such as orthodontic brackets, arch bar, and retention prosthesis. All these methods require specialized dental skills.2,6 The method of choice is dictated by each individual case. The presence of good dentition offers a wider selection of methods that can be used. In edentulous patients, ET tube fixation using IMF screw is a simple and safe method. The risks of this method are low and the advantages are many. This method should be considered in edentulous patients with severe facial burns.
  5 in total

1.  Endotracheal tube fixation to the maxilla in patients with facial burns.

Authors:  Charles Davis
Journal:  Plast Reconstr Surg       Date:  2004-03       Impact factor: 4.730

2.  External fixation of endotracheal tubes while skin grafting severe burns of the face.

Authors:  R H Hansen; J P Remensnyder
Journal:  Plast Reconstr Surg       Date:  1978-10       Impact factor: 4.730

3.  Circummandibular or nasomaxillary suture with pullout loop for secure placement of endotracheal tube.

Authors:  D W Furnas; G R Allison
Journal:  Am J Surg       Date:  1980-06       Impact factor: 2.565

4.  Endotracheal tube stabilization using an orthodontic skeletal anchor in a patient with facial burns.

Authors:  T Kanno; M Mitsugi; Y Furuki; S Kozato
Journal:  Int J Oral Maxillofac Surg       Date:  2008-03-04       Impact factor: 2.789

5.  Intermaxillary fixation screw for endotracheal tube fixation in the edentulous patient with facial burns.

Authors:  Y Fleissig; H Rushinek; E Regev
Journal:  Int J Oral Maxillofac Surg       Date:  2014-06-16       Impact factor: 2.789

  5 in total
  1 in total

1.  Oral to nasal endotracheal tube exchange using tracheal tube guide and video laryngoscope in a pediatric patient with facial burns: a case report.

Authors:  Naoki Yogo; Taeko Sasaki; Masato Kozumi; Yuya Kinoshita; Yuichiro Muto; Katsuki Hirai; Yuichiro Yoshino
Journal:  Int J Emerg Med       Date:  2022-09-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.