Abstract

A 51-year-old woman was referred with uncontrolled intraocular pressure (IOP) despite maximal medical IOP-lowering therapy. Her background included several failed glaucoma filtering surgeries, including aqueous drainage devices. Considering the need to perform surgery in a patient with both scarred conjunctiva and corneal endothelial deficiency, a surgical technique combining cornea-friendly XEN stent connected to a large-plate Baerveldt glaucoma implant was undertaken. Unfortunately, XEN implants obstructed twice during the early postoperative period. As further XEN replacements were unfeasible, there was the need to bridge the gap between the Baerveldt tube and the anterior chamber. An easy accessible, cheap 22G angiocatheter segment was used for this purpose. With a follow-up of 6 months, there were no postoperative complications nor loss of efficiency, with IOP of 7 mmHg. Tube extension using angiocatheter is a viable, cost-effective option in these difficult cases, saving the surgeon from having to explant and replace the entire implant. © BMJ Publishing Group Limited 2018. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  anterior chamber; glaucoma

Mesh:

Year:  2018        PMID: 30344156      PMCID: PMC6203078          DOI: 10.1136/bcr-2018-226958

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  7 in total

1.  Glaucoma drainage device tube extension without the need for a tube extender device or angiocatheter.

Authors:  Ashley Porter; Graham A Lee; Peter Shah; Brian Todd
Journal:  Clin Exp Ophthalmol       Date:  2016-09-20       Impact factor: 4.207

2.  Repair of Molteno implant during surgery.

Authors:  K S Kooner
Journal:  Am J Ophthalmol       Date:  1994-05-15       Impact factor: 5.258

3.  Extension of retracted glaucoma drainage tube using a 22-gauge intravenous catheter in complex pediatric glaucoma.

Authors:  Atul Bansal; Cecilia H Fenerty
Journal:  J Glaucoma       Date:  2010 Apr-May       Impact factor: 2.503

4.  Results of another modality for extending glaucoma drainage tubes.

Authors:  M F Smith; J W Doyle
Journal:  J Glaucoma       Date:  1999-10       Impact factor: 2.503

5.  XEN-augmented Baerveldt: A New Surgical Technique for Refractory Glaucoma.

Authors:  Elisa D'Alessandro; Jacopo M Guidotti; Kaweh Mansouri; André Mermoud
Journal:  J Glaucoma       Date:  2017-02       Impact factor: 2.503

6.  Fluid Dynamics of a Novel Micro-Fistula Implant for the Surgical Treatment of Glaucoma.

Authors:  Arsham Sheybani; Herbert Reitsamer; Iqbal Ike K Ahmed
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-07       Impact factor: 4.799

Review 7.  Tube shunt complications and their prevention.

Authors:  Steven R Sarkisian
Journal:  Curr Opin Ophthalmol       Date:  2009-03       Impact factor: 3.761

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.