Literature DB >> 30342215

A Hybrid Technique to Manage a Large Perigraft Seroma after an Open Abdominal Aortic Aneurysm Repair: A Case Report.

Shigeshi Ono1, Hideaki Obara2, Kazuki Hagiwara3, Fumitaka Saida3, Kentaro Oshiro3, Kentaro Matsubara4, Shintaro Shibutani3, Yuko Kitagawa4.   

Abstract

Perigraft seroma (PGS) is a relatively rare complication of aortoiliac reconstructive surgery. We, herein, describe a case of a large PGS that was managed by using a hybrid technique of relining the original graft with simultaneous open drainage. An 86-year-old man with a 17.3-cm diameter PGS after prosthetic bifurcated graft replacement for abdominal aortic aneurysm was admitted to our hospital. He presented with abdominal distension and discomfort and had difficulty in taking food. The entire relining of the original covered stent graft with GORE® EXCLUDER® using aortic extension cuff and iliac extenders and simultaneous open evacuation of PGS were successfully performed. The symptoms of the patient totally improved, and no recurrence was detected at 2 years after the operation. This technique would be a feasible treatment option for this rare complication.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30342215     DOI: 10.1016/j.avsg.2018.07.073

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  2 in total

1.  Endovascular treatment of perigraft seroma in patient with prior hybrid thoracoabdominal repair using visceral bypass to relieve duodenal obstruction.

Authors:  Tsutomu Doita; Kazuo Shimamura; Takayuki Shijo; Ryota Matsumoto; Shigeru Miyagawa
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-08-08

2.  Sac enlargement due to perigraft seroma and back-bleeding from the remnant wall 11 years after open surgical repair of an infected abdominal aortic aneurysm.

Authors:  Kazumasa Hanada; Katsuyuki Hoshina; Masamitsu Suhara; Ryosuke Taniguchi; Mitsuru Matsukura; Toshio Takayama
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-02-08
  2 in total