Literature DB >> 30340923

Proposal for a Novel Score to Determine the Risk of Cardiac Implantable Electronic Device Infection.

Jorge Calderón-Parra1, Enrique Sánchez-Chica2, Ángel Asensio-Vegas3, Ignacio Fernández-Lozano4, Jorge Toquero-Ramos4, Víctor Castro-Urda4, Ana Royuela-Vicente5, Antonio Ramos-Martínez2.   

Abstract

INTRODUCTION AND
OBJECTIVES: The use of cardiac implantable electronic devices (CIEDs) has expanded in recent years. Infection related to these devices constitutes one of the main complications and is associated with high morbidity, mortality, and financial cost. The aim of this study was to construct a predictive risk score of acquiring CIED infection.
METHODS: We designed a retrospective, nested case-control study. Both cases and controls belonged to a cohort that included all patients who underwent a CIED-related procedure between January 2009 and December 2015. Cases were defined as patients with infection, and 3 infection-free controls were randomly selected from the cohort for each case included.
RESULTS: During the study period, 2323 procedures were performed. A total of 33 CIED-related infections were identified. Ninety-nine patients were selected as controls. Independent risk factors were the Charlson index (OR, 1.33; 95%CI, 1.07-1.67), oral anticoagulation (OR, 3.51; 95%CI, 1.44-8.54), revision or replacement of a previous device (OR, 2.75; 95%CI, 1.12-6.71) and the presence of more than 2 leads (OR, 3.42; 95%CI, 1.25-9.37). A predictive risk score was generated and denominated CIED-AI (Charlson Index, more than 2 leads/Electrodes, Device revision/replacement, oral Anticoagulation, previous Infection). This score had an area under the receiver operating characteristic curve of 0.79 (95%CI, 0.71-0.88).
CONCLUSIONS: The CIED-AI score may help to identify patients at higher risk of infection, who could be candidates for intensive preventive measures.
Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  CIED-related infection; Calificación predictiva; Cardiac implantable electronic device; Dispositivo cardiaco implantable; Factor de riesgo; Infección relacionada con DCI; Predictive score; Risk factor

Mesh:

Substances:

Year:  2018        PMID: 30340923     DOI: 10.1016/j.rec.2018.09.003

Source DB:  PubMed          Journal:  Rev Esp Cardiol (Engl Ed)        ISSN: 1885-5857


  2 in total

1.  Postimplantation pocket hematoma increases risk of cardiac implantable electronic device infection: A meta-analysis.

Authors:  Jakrin Kewcharoen; Chanavuth Kanitsoraphan; Sittinun Thangjui; Thiratest Leesutipornchai; Sakditad Saowapa; Apichai Pokawattana; Leenhapong Navaravong
Journal:  J Arrhythm       Date:  2021-03-13

2.  Outcomes Associated With Infection of Chronic Pain Spinal Implantable Electronic Devices: Insights From a Nationwide Inpatient Sample Study.

Authors:  Vasudha Goel; Varun Kumar; Shivani N Agrawal; Amol M Patwardhan; Mohab Ibrahim; Daniel C DeSimone; Eellan Sivanesan; Ratan K Banik; Hariharan Shankar
Journal:  Neuromodulation       Date:  2020-09-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.