Literature DB >> 30340762

Ascending thoracic aorta aneurysm repair induces positive hemodynamic outcomes in a patient with unchanged bicuspid aortic valve.

Francesca Condemi1, Salvatore Campisi2, Magalie Viallon3, Pierre Croisille3, Jean-François Fuzelier2, Stéphane Avril4.   

Abstract

We report a patient-specific case of bicuspid aortic valve with fusion of right and left coronary leaflets (R-L type I BAV), moderate aortic valve deficiency and ascending thoracic aortic aneurysms (ATAA) who was treated by only ascending aorta replacement preserving the BAV. The flow eccentricity, the helicity intensity (h2), the circumferential time averaged wall shear stress (TAWSScircumferential), the cumulative viscous energy loss at the systolic peak (EL') and the pulse wave velocity (PWV) were calculated by combining 4D flow MRI and CFD analysis before (Stage I) and after (Stage II) the surgical procedure. CFD analyses assumed rigid walls, a non-Newtonian behavior for the blood and MRI measured patient-specific blood flow profiles as inlet boundary conditions. Stage II results showed suppression of recirculation in the ascending aorta, loss of jet flow impingement onto the aortic wall, maximum TAWSScircumferential decrease (from 6.69 Pa in Stage I to 6 Pa in Stage II), reduction of flow helicity (from 10.97 in Stage I to 8.47 in Stage II) and EL' (from 15.8 mW in Stage I to 11.2 mW in Stage II). However, Floweccentricity and PWV were found higher in Stage II due to the diameter reduction (Floweccentricity = 0.60 in Stage I and Floweccentricity = 0.91 in Stage II; PWV = 3.80 m/s in Stage I and PWV = 9.37 m/s in Stage II). Our work has permitted to compute for the first time the hemodynamic alterations obtained after restoration of normal ascending aorta and sinotubular junction geometry even preserving an R-L type I BAV with still acceptable function.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  4D MRI; Ascending thoracic aortic aneurysms; Bicuspid aortic valve; Computational fluid dynamics

Mesh:

Year:  2018        PMID: 30340762     DOI: 10.1016/j.jbiomech.2018.09.022

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Experimental and Mouse-Specific Computational Models of the Fbln4SMKO Mouse to Identify Potential Biomarkers for Ascending Thoracic Aortic Aneurysm.

Authors:  Marisa S Bazzi; Ramin Balouchzadeh; Shawn N Pavey; James D Quirk; Hiromi Yanagisawa; Vijay Vedula; Jessica E Wagenseil; Victor H Barocas
Journal:  Cardiovasc Eng Technol       Date:  2022-01-22       Impact factor: 2.305

Review 2.  Computational Hemodynamic Modeling of Arterial Aneurysms: A Mini-Review.

Authors:  Sarah N Lipp; Elizabeth E Niedert; Hannah L Cebull; Tyler C Diorio; Jessica L Ma; Sean M Rothenberger; Kimberly A Stevens Boster; Craig J Goergen
Journal:  Front Physiol       Date:  2020-05-12       Impact factor: 4.566

Review 3.  Hemodynamic Profiles Before and After Surgery in Bicuspid Aortic Valve Disease-A Systematic Review of the Literature.

Authors:  Daniel G W Cave; Hannah Panayiotou; Malenka M Bissell
Journal:  Front Cardiovasc Med       Date:  2021-03-24

4.  Computational analysis of aortic haemodynamics in the presence of ascending aortic aneurysm.

Authors:  Aleksandra Petuchova; Algirdas Maknickas
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.285

5.  Non-invasive diagnostics of blockage growth in the descending aorta-computational approach.

Authors:  Mohammad Al-Rawi; Ahmed M Al-Jumaily; Djelloul Belkacemi
Journal:  Med Biol Eng Comput       Date:  2022-09-27       Impact factor: 3.079

6.  Patient-Specific CT-Based Fluid-Structure-Interaction Aorta Model to Quantify Mechanical Conditions for the Investigation of Ascending Aortic Dilation in TOF Patients.

Authors:  Heng Zuo; Yunfei Ling; Peng Li; Qi An; Xiaobo Zhou
Journal:  Comput Math Methods Med       Date:  2020-08-08       Impact factor: 2.238

7.  Combining 4D Flow MRI and Complex Networks Theory to Characterize the Hemodynamic Heterogeneity in Dilated and Non-dilated Human Ascending Aortas.

Authors:  Karol Calò; Diego Gallo; Andrea Guala; Jose Rodriguez Palomares; Stefania Scarsoglio; Luca Ridolfi; Umberto Morbiducci
Journal:  Ann Biomed Eng       Date:  2021-06-02       Impact factor: 3.934

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.