Literature DB >> 30340212

Position-independent gesture recognition using sEMG signals via canonical correlation analysis.

Juan Cheng1, Fulin Wei1, Chang Li1, Yu Liu1, Aiping Liu2, Xun Chen3.   

Abstract

Gesture recognition based on surface electromyogram (sEMG) signals has drawn significant attention and obtained satisfactory achievement in the field of human-computer interaction. However, the same gesture performed with different arm positions tends not to generate the same sEMG signals. Traditional solutions can be divided into two types. One type treats the same gesture with different arm positions as the same type, leading to a relatively low classification rate. The other type adopts a gesture classifier followed by the position classifier, which will achieve a satisfactory classification accuracy but at the expenses of high training burdens. To address these issues, we propose a novel framework to explore the intrinsic position independent (PI) characteristics of sEMG signals generated from the same gesture with different arm positions by canonical correlation analysis (CCA), termed as PICCA. In this framework, with the bridge link of the predefined expert set, both the training set and the testing set can be mapped into a unified-style with CCA, and hence, the classification accuracy can be improved in both user-dependent and user-independent manners. Experimental results on 13 gestures with 3 arm positions indicate that the proposed PICCA can achieve higher classification rates than those without CCA (with 28.52% and 44.19% promotions during user-dependent and user-independent manners respectively) while maintaining acceptable training burdens. These improvements will facilitate the practical implementation of myoelectric interfaces.
Copyright © 2018. Published by Elsevier Ltd.

Entities:  

Keywords:  Canonical correlation analysis; Gesture recognition; Position independent; Surface electromyogram; User dependent; User independent

Mesh:

Year:  2018        PMID: 30340212     DOI: 10.1016/j.compbiomed.2018.08.020

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  3 in total

1.  Deep Cross-User Models Reduce the Training Burden in Myoelectric Control.

Authors:  Evan Campbell; Angkoon Phinyomark; Erik Scheme
Journal:  Front Neurosci       Date:  2021-05-24       Impact factor: 4.677

2.  Rejecting Novel Motions in High-Density Myoelectric Pattern Recognition Using Hybrid Neural Networks.

Authors:  Le Wu; Xun Chen; Xiang Chen; Xu Zhang
Journal:  Front Neurorobot       Date:  2022-03-28       Impact factor: 2.650

3.  Current Trends and Confounding Factors in Myoelectric Control: Limb Position and Contraction Intensity.

Authors:  Evan Campbell; Angkoon Phinyomark; Erik Scheme
Journal:  Sensors (Basel)       Date:  2020-03-13       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.