| Literature DB >> 30340203 |
Teddy X Cai1, Dan Benjamini2, Michal E Komlosh3, Peter J Basser2, Nathan H Williamson4.
Abstract
Diffusion exchange spectroscopy (DEXSY) provides a detailed picture of how fluids in different microenvironments communicate with one another but requires a large amount of data. For DEXSY MRI, a simple measure of apparent exchanging fractions may suffice to characterize and differentiate materials and tissues. Reparameterizing signal intensity from a PGSE-storage-PGSE experiment as a function of the sum, bs=b1+b2, and difference bd=b2-b1 of the diffusion encodings separates diffusion weighting from exchange weighting. Exchange leads to upward curvature along a slice of constant bs. Exchanging fractions can be measured rapidly by a finite difference approximation of the curvature using four data points. The method is generalized for non-steady-state and multi-site exchange. We apply the method to image exchanging fractions and calculate exchange rates of water diffusing across the bulk water interface of a glass capillary array. Published by Elsevier Inc.Entities:
Keywords: Apparent exchange rate; Exchange-weighted imaging; Inverse Laplace; Permeability; Porous media; Pulsed gradient spin echo NMR; Time-domain analysis; Transcytolemmal water exchange
Year: 2018 PMID: 30340203 PMCID: PMC6289744 DOI: 10.1016/j.jmr.2018.10.004
Source DB: PubMed Journal: J Magn Reson ISSN: 1090-7807 Impact factor: 2.229