Literature DB >> 30340195

Development and optimization of a QuEChERS-GC-MS/MS methodology to analyse ultraviolet-filters and synthetic musks in sewage sludge.

Sara Ramos1, Vera Homem2, Lúcia Santos1.   

Abstract

A Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) methodology followed by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) analysis was developed to extract synthetic musk compounds (SMCs) (6 polycyclic, 2 macrocyclic and 5 nitro musks) and ultraviolet-filters (UVFs) (6 compounds) from sludge. This methodology fills a gap in the literature, since the proposed technique does not require specific equipment, nor large amounts of solvents, sorbents and time to extract SMCs and UVFs from sludge. To optimize this new methodology, a design of experiments (DoE) approach was used, applying first a screening design (SD) and then a central composite design (CCD). The best conditions achieved to extract these 19 compounds simultaneously were: 500 mg freeze dried sludge, 2.5 min of vortex and 15 min ultrasound and the use of a QuEChERS for the dispersive solid-phase extraction (d-SPE) containing 500 mg MgSO4, 410 mg C18 and 315 mg PSA. Then, this methodology was successfully validated. Recoveries of the target compounds ranged from 75% (cashmeran, DPMI) to 122% (2‑ethylhexyl 4‑methoxycinnamate, EHMC), with good repeatability (relative standard deviation < 10%). The instrumental detection limits (IDLs) and quantification (IQLs) varied from 0.001 pg (musk moskene, MM) to 7.5 pg (musk xylene, MX) and from 0.003 (MM) to 25 pg (MX), respectively. The method detection and quantification limits (MDLs and MQLs) ranged between 0.5 (DPMI) and 1394 (exaltolide, EXA) ng/g dw and 2 and 4648 ng/g-dw, respectively. Both SMCs and UVFs were detected in all sludge samples analysed. Higher concentrations were found for octocrylene (OC: maximum value of 115,486 ng/g-dw) followed by galaxolide (HHCB: 81,771 ng/g-dw). Only the nitro musks ambrette, xylene, moskene and tibetene and macrocyclic musk ethylene brassylate (EB) were not detected in any sample.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Design of experiments; GC–MS/MS; QuEChERS; Sludge; Synthetic musk compounds; UV-filters

Year:  2018        PMID: 30340195     DOI: 10.1016/j.scitotenv.2018.10.143

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  2 in total

1.  Enhanced Toxicity of Bisphenols Together with UV Filters in Water: Identification of Synergy and Antagonism in Three-Component Mixtures.

Authors:  Błażej Kudłak; Natalia Jatkowska; Wen Liu; Michael J Williams; Damia Barcelo; Helgi B Schiöth
Journal:  Molecules       Date:  2022-05-19       Impact factor: 4.927

2.  Using Design of Experiments to Optimize a Screening Analytical Methodology Based on Solid-Phase Microextraction/Gas Chromatography for the Determination of Volatile Methylsiloxanes in Water.

Authors:  Fábio Bernardo; Providencia González-Hernández; Nuno Ratola; Verónica Pino; Arminda Alves; Vera Homem
Journal:  Molecules       Date:  2021-06-05       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.