Literature DB >> 30339639

Unwanted Astigmatism and High-order Aberrations One Year after Excimer and Femtosecond Corneal Surgery.

Maja Bohac1, Mateja Koncarevic1,2, Adrijana Dukic1,2, Alma Biscevic1,2, Vesna Cerovic1,2, Maja Merlak2,3, Nikica Gabric1,2, Sudi Patel1,4.   

Abstract

SIGNIFICANCE: Small incision lenticule extraction (SMILE) is advanced as the most minimally invasive and least traumatic corneal procedure for correcting refractive errors using a single laser. Although SMILE obtains similar results to femtosecond laser in situ keratomileusis (LASIK) with spherical myopia, it has deficiencies in astigmatism correction.
PURPOSE: The purpose of this study was to compare refractive outcomes and high-order aberrations (HOAs) between SMILE and femtosecond LASIK corneal procedures at 1 year post-operative.
METHODS: Ninety-two patients (181 eyes) with myopia/myopic astigmatism underwent either SMILE (group 1) or femtosecond LASIK (group 2). The refractive target was to achieve emmetropia in all cases. Data were analyzed to determine significance of change in refraction and HOAs. Furthermore, astigmatism was subjected to vector analysis using the Thibos (calculation of change, Δ, in J0 and J45 values) and Alpins (calculation of difference, ΔC, between target-induced astigmatism [TIA] and surgically induced astigmatism) methods.
RESULTS: Forty-five patients (89 eyes) from group 1 and 47 patients (92 eyes) from group 2 completed the study. The main significant (P ≤ .001) findings were as follows: (a) residual astigmatism was greater in group 1; (b) group 1, ΔJ0 = 1.015J0 + 0.040 (R = 0.861), ΔJ45 = 1.082J45 + 0.019 (R = 0.792), ΔC = 0.401TIA + 0.323 (R = 0.489), and mean spherical aberration increased from -0.003 (SD, ±0.059; 95% confidence interval [CI], -0.015 to 0.009) to 0.028 μm (SD, ±0.041; 95% CI, -0.037 to -0.020); and (c) group 2, ΔJ0 = 0.952J0 - 0.005 (R = 0.921), ΔJ45 = 0.962J45 - 0.002 (R = 0.923), ΔC = 0.187TIA + 0.101 (R = 0.272), mean coma reduced from 0.114 (SD, ±0.087; 95% CI, 0.096 to 0.132) to 0.077 μm (SD, ±0.059; 95% CI, 0.065 to 0.089), and trefoil from 0.089 (SD, ±0.049; 95% CI, 0.079 to 0.0990) to 0.056 μm (SD, ±0.047; 95% CI, 0.046 to 0.066).
CONCLUSIONS: In comparison with SMILE, femtosecond LASIK offered better precision in the overall control of astigmatism and HOAs.

Entities:  

Mesh:

Year:  2018        PMID: 30339639     DOI: 10.1097/OPX.0000000000001298

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  4 in total

1.  Excimer Laser Corneal Refractive Surgery in the Clinic: A Systematic Review and Meta-analysis.

Authors:  Huang Zhang; Mingming Li; Zhimin Cen
Journal:  Comput Math Methods Med       Date:  2022-06-15       Impact factor: 2.809

2.  Effect of Postoperative Ocular Residual Astigmatism (ORA) on Treatment Outcome After Myopic Laser in situ Keratomileusis (LASIK).

Authors:  Johanna Nöthel; Toam Katz; Vasyl Druchkiv; Andreas Frings
Journal:  Clin Ophthalmol       Date:  2022-06-23

3.  Comparison of visual outcomes between 120-µm and 140-µm cap thicknesses 12 months after small incision lenticule extraction.

Authors:  Mehmet Gülmez; Özlem Ural Fatihoğlu; Abdülhakim Tekçe
Journal:  Lasers Med Sci       Date:  2022-02-26       Impact factor: 2.555

4.  Corneal morphological changes after small incision lenticule extraction for myopic anisometropia.

Authors:  Lu Zhu; Yan Ji; Xin Yang; Xiaorong Lu; Qiong Wu; Qing Wang; Jiuyi Xia; Meng Li; Ke Hu; Wenjuan Wan
Journal:  Front Med (Lausanne)       Date:  2022-08-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.