Literature DB >> 30336861

Lung volumes, respiratory mechanics and dynamic strain during general anaesthesia.

D L Grieco1, A Russo2, B Romanò2, G M Anzellotti2, P Ciocchetti2, F Torrini2, R Barelli2, D Eleuteri2, V Perilli2, A M Dell'Anna2, F Bongiovanni2, L Sollazzi2, M Antonelli2.   

Abstract

BACKGROUND: Driving pressure (ΔP) represents tidal volume normalised to respiratory system compliance (CRS) and is a novel parameter to target ventilator settings. We conducted a study to determine whether CRS and ΔP reflect aerated lung volume and dynamic strain during general anaesthesia.
METHODS: Twenty non-obese patients undergoing open abdominal surgery received three PEEP levels (2, 7, or 12 cm H2O) in random order with constant tidal volume ventilation. Respiratory mechanics, lung volumes, and alveolar recruitment were measured to assess end-expiratory aerated volume, which was compared with the patient's individual predicted functional residual capacity in supine position (FRCp).
RESULTS: CRS was linearly related to aerated volume and ΔP to dynamic strain at PEEP of 2 cm H2O (intraoperative FRC) (r=0.72 and r=0.73, both P<0.001). These relationships were maintained with higher PEEP only when aerated volume did not overcome FRCp (r=0.73, P<0.001; r=0.54, P=0.004), with 100 ml lung volume increases accompanied by 1.8 ml cm H2O-1 (95% confidence interval [1.1-2.5]) increases in CRS. When aerated volume was greater or equal to FRCp (35% of patients at PEEP 2 cm H2O, 55% at PEEP 7 cm H2O, and 75% at PEEP 12 cm H2O), CRS and ΔP were independent from aerated volume and dynamic strain, with CRS weakly but significantly inversely related to alveolar dead space fraction (r=-0.47, P=0.001). PEEP-induced alveolar recruitment yielded higher CRS and reduced ΔP only at aerated volumes below FRCp (P=0.015 and 0.008, respectively).
CONCLUSIONS: During general anaesthesia, respiratory system compliance and driving pressure reflect aerated lung volume and dynamic strain, respectively, only if aerated volume does not exceed functional residual capacity in supine position, which is a frequent event when PEEP is used in this setting.
Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  functional residual capacity; positive end-expiratory pressure; respiratory mechanics

Mesh:

Year:  2018        PMID: 30336861     DOI: 10.1016/j.bja.2018.03.022

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  11 in total

1.  A personalized approach to the acute respiratory distress syndrome: recent advances and future challenges.

Authors:  Elena Spinelli; Domenico L Grieco; Tommaso Mauri
Journal:  J Thorac Dis       Date:  2019-12       Impact factor: 2.895

Review 2.  Should we titrate ventilation based on driving pressure? Maybe not in the way we would expect.

Authors:  Paolo Pelosi; Lorenzo Ball
Journal:  Ann Transl Med       Date:  2018-10

Review 3.  Respiratory mechanics during general anaesthesia.

Authors:  Lorenzo Ball; Federico Costantino; Martina Fiorito; Sara Amodio; Paolo Pelosi
Journal:  Ann Transl Med       Date:  2018-10

4.  Individualized PEEP to optimise respiratory mechanics during abdominal surgery: a pilot randomised controlled trial.

Authors:  Ana Fernandez-Bustamante; Juraj Sprung; Robert A Parker; Karsten Bartels; Toby N Weingarten; Carolina Kosour; B Taylor Thompson; Marcos F Vidal Melo
Journal:  Br J Anaesth       Date:  2020-07-16       Impact factor: 9.166

Review 5.  Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions.

Authors:  Elena Spinelli; Tommaso Mauri; Alberto Fogagnolo; Gaetano Scaramuzzo; Annalisa Rundo; Domenico Luca Grieco; Giacomo Grasselli; Carlo Alberto Volta; Savino Spadaro
Journal:  BMC Anesthesiol       Date:  2019-08-07       Impact factor: 2.217

6.  Tidal Volume Lowering by Instrumental Dead Space Reduction in Brain-Injured ARDS Patients: Effects on Respiratory Mechanics, Gas Exchange, and Cerebral Hemodynamics.

Authors:  Sara Pitoni; Sonia D'Arrigo; Domenico Luca Grieco; Francesco Antonio Idone; Maria Teresa Santantonio; Pierluigi Di Giannatale; Alessandro Ferrieri; Daniele Natalini; Davide Eleuteri; Bjorn Jonson; Massimo Antonelli; Salvatore Maurizio Maggiore
Journal:  Neurocrit Care       Date:  2020-04-22       Impact factor: 3.210

7.  Changes in diaphragmatic excursion and lung compliance during gynaecologic surgery: open laparotomy versus laparoscopy-a prospective observational study.

Authors:  Kyungmi Kim; Kyoung-Sun Kim; A Rom Jeon; Jong-Yeon Park; Woo-Jong Choi
Journal:  Sci Rep       Date:  2020-12-08       Impact factor: 4.379

8.  Lung Recruitability and Positive End-Expiratory Pressure Setting in ARDS Caused by COVID-19.

Authors:  Domenico Luca Grieco; Gennaro De Pascale; Massimo Antonelli
Journal:  Chest       Date:  2022-04       Impact factor: 10.262

9.  Reply to Rezoagli et al.: CO2 Oscillation during Cardiopulmonary Resuscitation: The Role of Respiratory System Compliance.

Authors:  Domenico L Grieco; Laurent Brochard; Jean-Christophe M Richard
Journal:  Am J Respir Crit Care Med       Date:  2019-05-15       Impact factor: 21.405

10.  Respiratory physiology of COVID-19-induced respiratory failure compared to ARDS of other etiologies.

Authors:  Domenico Luca Grieco; Filippo Bongiovanni; Lu Chen; Luca S Menga; Salvatore Lucio Cutuli; Gabriele Pintaudi; Simone Carelli; Teresa Michi; Flava Torrini; Gianmarco Lombardi; Gian Marco Anzellotti; Gennaro De Pascale; Andrea Urbani; Maria Grazia Bocci; Eloisa S Tanzarella; Giuseppe Bello; Antonio M Dell'Anna; Salvatore M Maggiore; Laurent Brochard; Massimo Antonelli
Journal:  Crit Care       Date:  2020-08-28       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.