Literature DB >> 30336265

Pseudo-CT Generation for MRI-Only Radiation Therapy Treatment Planning: Comparison Among Patch-Based, Atlas-Based, and Bulk Density Methods.

Axel Largent1, Anaïs Barateau2, Jean-Claude Nunes2, Caroline Lafond2, Peter B Greer3, Jason A Dowling4, Hervé Saint-Jalmes2, Oscar Acosta2, Renaud de Crevoisier2.   

Abstract

PURPOSE: Methods have been recently developed to generate pseudo-computed tomography (pCT) for dose calculation in magnetic resonance imaging (MRI)-only radiation therapy. This study aimed to propose an original nonlocal mean patch-based method (PBM) and to compare this PBM to an atlas-based method (ABM) and to a bulk density method (BDM) for prostate MRI-only radiation therapy.
MATERIALS AND METHODS: Thirty-nine patients received a volumetric modulated arc therapy for prostate cancer. In addition to the planning computed tomography (CT) scans, T2-weighted MRI scans were acquired. pCTs were generated from MRIs using 3 methods: an original nonlocal mean PBM, ABM, and BDM. The PBM was performed using feature extraction and approximate nearest neighbor search in a training cohort. The PBM accuracy was evaluated in a validation cohort by using imaging and dosimetric endpoints. Imaging endpoints included mean absolute error and mean error between Hounsfield units of the pCT and the reference CT (CTref). Dosimetric endpoints were based on dose-volume histograms calculated from the CTref and the pCTs for various volumes of interest and on 3-dimensional gamma analyses. The PBM uncertainties were compared with those of the ABM and BDM.
RESULTS: The mean absolute error and mean error obtained from the PBM were 41.1 and -1.1 Hounsfield units. The PBM dose-volume histogram differences were 0.7% for prostate planning target volume V95%, 0.5% for rectum V70Gy, and 0.2% for bladder V50Gy. Compared with ABM and BDM, PBM provided significantly lower dose uncertainties for the prostate planning target volume (70-78 Gy), the rectum (8.5-29 Gy, 40-48 Gy, and 61-73 Gy), and the bladder (12-78 Gy). The PBM mean gamma pass rate (99.5%) was significantly higher than that of ABM (94.9%) or BDM (96.1%).
CONCLUSIONS: The proposed PBM provides low uncertainties with dose planned on CTref. These uncertainties were smaller than those of ABM and BDM and are unlikely to be clinically significant.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30336265     DOI: 10.1016/j.ijrobp.2018.10.002

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  MRI-based synthetic CT generation using semantic random forest with iterative refinement.

Authors:  Yang Lei; Joseph Harms; Tonghe Wang; Sibo Tian; Jun Zhou; Hui-Kuo Shu; Jim Zhong; Hui Mao; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

2.  MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method.

Authors:  Yingzi Liu; Yang Lei; Tonghe Wang; Oluwatosin Kayode; Sibo Tian; Tian Liu; Pretesh Patel; Walter J Curran; Lei Ren; Xiaofeng Yang
Journal:  Br J Radiol       Date:  2019-06-20       Impact factor: 3.039

3.  Applying MRI Intensity Normalization on Non-Bone Tissues to Facilitate Pseudo-CT Synthesis from MRI.

Authors:  Kuei-Yuan Hou; Hao-Yuan Lu; Ching-Ching Yang
Journal:  Diagnostics (Basel)       Date:  2021-04-30

4.  MRI-based treatment planning for proton radiotherapy: dosimetric validation of a deep learning-based liver synthetic CT generation method.

Authors:  Yingzi Liu; Yang Lei; Yinan Wang; Tonghe Wang; Lei Ren; Liyong Lin; Mark McDonald; Walter J Curran; Tian Liu; Jun Zhou; Xiaofeng Yang
Journal:  Phys Med Biol       Date:  2019-07-16       Impact factor: 3.609

5.  Bulk Anatomical Density Based Dose Calculation for Patient-Specific Quality Assurance of MRI-Only Prostate Radiotherapy.

Authors:  Jae Hyuk Choi; Danny Lee; Laura O'Connor; Stephan Chalup; James S Welsh; Jason Dowling; Peter B Greer
Journal:  Front Oncol       Date:  2019-10-02       Impact factor: 6.244

6.  Assessment of dosimetric and positioning accuracy of a magnetic resonance imaging-only solution for external beam radiotherapy of pelvic anatomy.

Authors:  Reko Kemppainen; Sami Suilamo; Iiro Ranta; Marko Pesola; Aleksi Halkola; Alvin Eufemio; Heikki Minn; Jani Keyriläinen
Journal:  Phys Imaging Radiat Oncol       Date:  2019-06-22
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.