Literature DB >> 30336020

Delayed Sensor Activation Based on Transient Coatings: Biofouling Protection in Complex Biofluids.

Víctor Ruiz-Valdepeñas Montiel1,2, Juliane R Sempionatto1, Berta Esteban-Fernández de Ávila1, Amelia Whitworth1, Susana Campuzano2, José M Pingarrón2, Joseph Wang1.   

Abstract

Transient polymeric coatings with a programmable transiency behavior are used for delayed exposure of fresh surfaces of multi-electrode sensor arrays at preselected times. Such delayed sensor actuation is shown to be extremely attractive for addressing severe biofouling characteristic of electrochemical biosensors in complex biofluids. Controlled coating dissolution and tunable sequential actuation of the individual sensing electrodes are achieved by tailoring the characteristics of the coating (density and thickness). The unique features offered by these delayed sensors allowed direct glucose monitoring in untreated blood and saliva samples over prolonged periods. This attractive delayed-sensor exposure concept, offering time-tunable sequential activation of multiple sensors with remarkable anti-biofouling properties, indicates considerable promise for operating sensors continuously in complex body fluids.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30336020     DOI: 10.1021/jacs.8b08894

Source DB:  PubMed          Journal:  J Am Chem Soc        ISSN: 0002-7863            Impact factor:   15.419


  4 in total

Review 1.  In-Plane Si Microneedles: Fabrication, Characterization, Modeling and Applications.

Authors:  Abdulla Al Mamun; Feng Zhao
Journal:  Micromachines (Basel)       Date:  2022-04-20       Impact factor: 3.523

Review 2.  Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices.

Authors:  Susana Campuzano; María Pedrero; Maria Gamella; Verónica Serafín; Paloma Yáñez-Sedeño; José Manuel Pingarrón
Journal:  Sensors (Basel)       Date:  2020-06-16       Impact factor: 3.576

Review 3.  Recent Developments of Electrochemical and Optical Biosensors for Antibody Detection.

Authors:  Wei Xu; Daniel Wang; Derek Li; Chung Chiun Liu
Journal:  Int J Mol Sci       Date:  2019-12-24       Impact factor: 5.923

4.  Amperometric Monitoring of Dissolution of pH-Responsive EUDRAGIT® Polymer Film Coatings.

Authors:  Júlia Mestres; Francesca Leonardi; Klaus Mathwig
Journal:  Micromachines (Basel)       Date:  2022-02-25       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.