Literature DB >> 30328736

Accounting for effects of system dynamics to improve accuracy of emissions reported in e-cig vaping machines.

E C Hensel1, S Jayasekera1, R J Robinson1.   

Abstract

Laboratory emissions testing of electronic cigarettes continues to be a focus in the tobacco research community. In particular, to inform policy regarding appropriate test protocols to regulate the manufacture, marketing and sale of tobacco products. This study aims to enhance current understanding of the way laboratory systems used to generate topography profiles and capture resultant emissions from inhaled tobacco products may interact with the device under test. A programmable emission system (vaping machine) is introduced and characterized. The operating envelope of this system is presented. This study demonstrates that the performance of an emissions system may be influenced by various factors, resulting in discrepancies between command puff parameter inputs and the observed puffs generated. The study findings conclude that any emissions system should be characterized with the desired test device to determine the effective operating range of the system under "Load" conditions. Furthermore, reporting emissions from electronic cigarettes as a function of "command" puff flow rate and cumulative volume result in under-estimation bias and may give rise to incorrect conclusions regarding the impact of product characteristics on emissions. Conversely, reporting emissions in terms of "observed" puff flow rate and cumulative volume reduces bias errors and limits opportunity for intentional misrepresentation of results.

Entities:  

Keywords:  Electronic cigarette; emissions; flow rate; protocol; regulatory science; topography; vaping machine

Mesh:

Substances:

Year:  2018        PMID: 30328736     DOI: 10.1080/08958378.2018.1526232

Source DB:  PubMed          Journal:  Inhal Toxicol        ISSN: 0895-8378            Impact factor:   2.724


  3 in total

1.  A Comparison between Cigarette Topography from a One-Week Natural Environment Study to FTC/ISO, Health Canada, and Massachusetts Department of Public Health Puff Profile Standards.

Authors:  Risa J Robinson; S Emma Sarles; Shehan Jayasekera; Aziz Al Olayan; A Gary Difrancesco; Nathan C Eddingsaas; Edward C Hensel
Journal:  Int J Environ Res Public Health       Date:  2020-05-15       Impact factor: 3.390

2.  Effects of Manufacturing Variation in Electronic Cigarette Coil Resistance and Initial Pod Mass on Coil Lifetime and Aerosol Generation.

Authors:  Qutaiba M Saleh; Edward C Hensel; Nathan C Eddingsaas; Risa J Robinson
Journal:  Int J Environ Res Public Health       Date:  2021-04-20       Impact factor: 3.390

3.  Nominal Operating Envelope of Pod and Pen Style Electronic Cigarettes.

Authors:  Edward C Hensel; Nathan C Eddingsaas; Qutaiba M Saleh; Shehan Jayasekera; S Emma Sarles; Mahagani Thomas; Bryan T Myers; Gary DiFrancesco; Risa J Robinson
Journal:  Front Public Health       Date:  2021-08-17
  3 in total