Literature DB >> 30328190

A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns.

Bjarni E Pjetursson1,2, Nicola A Valente2, Malin Strasding2, Marcel Zwahlen3, Shiming Liu2,4, Irena Sailer2.   

Abstract

OBJECTIVES: The aim of the present systematic review was to analyze the survival and complication rates of zirconia-based and metal-ceramic implant-supported single crowns (SCs).
MATERIALS AND METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective cohort and retrospective case series on implant-supported SCs with a mean follow-up time of at least 3 years. Patients had to have been clinically examined at the follow-up visit. Assessment of the identified studies and data extraction was performed independently by two reviewers. Failure and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions.
RESULTS: The search provided 5,263 titles and 455 abstracts, full-text analysis was performed for 240 articles, resulting in 35 included studies on implant-supported crowns. Meta-analysis revealed an estimated 5-year survival rate of 98.3% (95% CI: 96.8-99.1) for metal-ceramic implant supported SCs (n = 4,363) compared to 97.6% (95% CI: 94.3-99.0) for zirconia implant supported SCs (n = 912). About 86.7% (95% CI: 80.7-91.0) of the metal-ceramic SCs (n = 1,300) experienced no biological/technical complications over the entire observation period. The corresponding rate for zirconia SCs (n = 76) was 83.8% (95% CI: 61.6-93.8). The biologic outcomes of the two types of crowns were similar; yet, zirconia SCs exhibited less aesthetic complications than metal-ceramics. The 5-year incidence of chipping of the veneering ceramic was similar between the material groups (2.9% metal-ceramic, 2.8% zirconia-ceramic). Significantly (p = 0.001), more zirconia-ceramic implant SCs failed due to material fractures (2.1% vs. 0.2% metal-ceramic implant SCs). No studies on newer types of monolithic zirconia SCs fulfilled the simple inclusion criteria of 3 years follow-up time and clinical examination of the present systematic review.
CONCLUSION: Zirconia-ceramic implant-supported SCs are a valid treatment alternative to metal-ceramic SCs, with similar incidence of biological complications and less aesthetic problems. The amount of ceramic chipping was similar between the material groups; yet, significantly more zirconia crowns failed due to material fractures.
© 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  biological; complications; fixed dental prostheses; implant crown; meta-analysis; metal-ceramics; success; survival; systematic review; technical; zirconia framework

Mesh:

Substances:

Year:  2018        PMID: 30328190     DOI: 10.1111/clr.13306

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  35 in total

1.  Comparison of marginal microleakage of metal copings cemented with three luting cements.

Authors:  Keyla Vargas-Belón; Katya Chambilla-Torres; Marco Sánchez-Tito
Journal:  J Clin Exp Dent       Date:  2022-03-01

2.  The Main Bacterial Communities Identified in the Sites Affected by Periimplantitis: A Systematic Review.

Authors:  Simina Angela Lăcrimioara Iușan; Ondine Patricia Lucaciu; Nausica Bianca Petrescu; Ioana Codruța Mirică; Dan-Alexandru Toc; Silviu Albu; Carmen Costache
Journal:  Microorganisms       Date:  2022-06-16

3.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

4.  Forensic and reliability analyses of fixed dental prostheses.

Authors:  John J Mecholsky; Shu-Min Hsu; Osama Jadaan; Jason Griggs; Daniel Neal; Arthur E Clark; Xinyi Xia; Josephine F Esquivel-Upshaw
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2021-02-01       Impact factor: 3.405

Review 5.  Monolithic Zirconia: An Update to Current Knowledge. Optical Properties, Wear, and Clinical Performance.

Authors:  Eleana Kontonasaki; Athanasios E Rigos; Charithea Ilia; Thomas Istantsos
Journal:  Dent J (Basel)       Date:  2019-09-02

Review 6.  Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis.

Authors:  Babak Saravi; Andreas Vollmer; Maja Hartmann; Gernot Lang; Ralf-Joachim Kohal; Martin Boeker; Sebastian B M Patzelt
Journal:  Materials (Basel)       Date:  2021-05-20       Impact factor: 3.623

7.  Technical and Biological Complications of Screw-Retained (CAD/CAM) Monolithic and Partial Veneer Zirconia for Fixed Dental Prostheses on Posterior Implants Using a Digital Workflow: A 3-Year Cross-Sectional Retrospective Study.

Authors:  Paolo De Angelis; Giulio Gasparini; Francesca Camodeca; Silvio De Angelis; Margherita Giorgia Liguori; Edoardo Rella; Francesca Cannata; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-07-06       Impact factor: 3.411

8.  Single-crown restorations supported by short implants (6 mm) compared with standard-length implants (13 mm) in conjunction with maxillary sinus floor augmentation: a randomized, controlled clinical trial.

Authors:  Helle Baungaard Nielsen; Søren Schou; Niels Henrik Bruun; Thomas Starch-Jensen
Journal:  Int J Implant Dent       Date:  2021-07-16

Review 9.  Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry.

Authors:  Se-Wook Pyo; Dae-Joon Kim; Jung-Suk Han; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

10.  Failure Modes and Survival of Anterior Crowns Supported by Narrow Implant Systems.

Authors:  Edmara T P Bergamo; Everardo N S de Araújo-Júnior; Adolfo C O Lopes; Paulo G Coelho; Abbas Zahoui; Ernesto B Benalcázar Jalkh; Estevam A Bonfante
Journal:  Biomed Res Int       Date:  2020-09-07       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.