| Literature DB >> 30327766 |
Megha A Deshmukh1, Gajanan A Bodkhe1, Sumedh Shirsat2, Arunas Ramanavicius3,4, Mahendra D Shirsat1.
Abstract
Heavy metal ions are consideredEntities:
Keywords: conducting polymer; electrochemical detection; ethylenediaminetetraacetic acid (EDTA); nanocomposite; single walled carbon nanotubes
Year: 2018 PMID: 30327766 PMCID: PMC6174202 DOI: 10.3389/fchem.2018.00451
Source DB: PubMed Journal: Front Chem ISSN: 2296-2646 Impact factor: 5.221
Figure 1Cyclic voltammogram during electrochemical deposition of unmodified (A) Ppy and (B) Ppy/SWNTs nanocomposite at a scan rate of 50 mV s−1.
Figure 2(A) Cyclic voltammograms and (B) electrochemical impedance spectra (EIS) obtained at unmodified Ppy, Ppy/SWNTs and EDTA-Ppy/SWNTs modified SS in the solution of 0.5 M LiClO4.
Figure 3(A) FTIR spectra, (B) Raman spectra, and (C) XRD spectra registered at unmodified Ppy, Ppy/SWNTs, and EDTA-Ppy/SWNTs modified electrodes.
Figure 4SEM images of (A) unmodified Ppy (B) Ppy/SWNTs, and (C) EDTA-Ppy/SWNTs.
Figure 5DPV based response of electrodes covered by unmodified Ppy, Ppy/SWNTs and EDTA-Ppy/SWNTs toward 8 × 102 μM Pb(II) ions dissolved in 0.2 M ABS pH 4.9, by the accumulation of metal ions by dip coating technique followed by stripping with DPV technique. The applied DPV parameters viz. increment of 5 mV, the step amplitude of 50 mV and a pulse period of 0.2 s in 0.5 M H2SO4.
Figure 6Influence of supporting electrolyte for Pb(II) ions in 0.2 M ABS and 0.5 M H2SO4 using EDTA-Ppy/SWNTs electrode.
Figure 7DPV responses and the corresponding hyperbolic calibration plots on EDTA-Ppy/SWNTs modified SS electrode during individual determination of Pb(II) ions within a concentration range of 8 × 102 μM to 0.15 μM for Pb(II) (A1). (A2, A3) represent peak currents plotted against Pb(II) concentrations in shorter concentration approximated by hyperbolic equation y = a–b/(1 + c × x)∧(1/d).
A1 and B1 represent corresponding parameters of applied hyperbolic equation, supporting electrolyte, 0.5 M H2SO4.
| Equation | Y = a–b(1 + c*x)∧(1/d) | |
| Reduced Chi-Sqr. | 0.00788 | |
| Adj. R-Square | 0.8634 | |
| B1 | Value | Standard Error |
| a 0.76329 | 0.0662 | |
| b 0.56927 | 0.12359 | |
| c − 0.01667 | 0.40715 | |
| d − 0.09739 | 2.48416 |
Figure 8DPV responses on the EDTA-Ppy/SWNTs modified SS electrode for selective detection of Pb(II) ions in presence of the foreign metal ions viz Cd(II), Zn(II), Mg(II), Ni(II), and Hg(II) within the concentration range of 8 × 102 μM.
Comparative study of the proposed method with other techniques for Pb(II) ion detection.
| 01 | Unfolded fullerene quantum dots | Optical | 2.5 μM | Ciotta et al., |
| 02 | Nitrogen-doped microporous carbon/Nafion/bismuth-film electrode | Differential pulse anodic stripping voltammetry | 0.05 μg L−1 | Xiao et al., |
| 03 | Bismuth modified exfoliated graphite (EG) electrode | Square wave anodic stripping voltammetry | 0.83 μg L−1 | Mafa et al., |
| 04 | Size controlled AuNPs/CNFs hybrid | Square wave anodic stripping voltammetry | 0.1 μM | Zhang et al., |
| 05 | Graphene-polyaniline nanocomposite | Anodic stripping voltammetry | 0.1 μg L−1 | Ruecha et al., |
| 06 | Dendritic bismuth film | Square wave stripping voltammetry | 5 μg L−1 | Zhou H. et al., |
| 07 | Bi/multiwalled carbon nanotube-emeraldine base polyaniline-Nafion composite modified glassy carbon electrode | Stripping voltammetry | 0.08 μg/L | Zhou G. et al., |
| 08 | Bismuth/glassy carbon composite | Anodic stripping voltammetry | 0.41 μg/L | Hwang et al., |
| 09 | Bismuth/electrochemically reduced grapheme/ionic liquid composite modified screen printed electrode. | Square wave anodic stripping voltammetry | 0.10 μg L−1 | Wang et al., |
| 10 | Iron oxide/grapheme composite | Differential pulse anodic stripping voltammetry | 0.07 μg L−1 | Lee et al., |