Literature DB >> 30327115

A cotton thread fluidic device with a wall-jet pencil-drawn paper based dual electrode detector.

Nicolò Dossi1, Rosanna Toniolo2, Fabio Terzi3, Nicola Sdrigotti2, Franco Tubaro2, Gino Bontempelli2.   

Abstract

A simple and sensitive device is presented based on the use of pencil-drawn paper based electrochemical detector placed at the end of a cotton thread fluidic channel in wall-jet configuration. This innovative and fast responding electroanalytical system can be adopted for both single and dual electrode electrochemical detection, this last achieved by applying two different potentials at two independent working electrodes drawn on the opposite faces of the paper based detector. Its performance was preliminarily optimized by adopting hexacyanoferrate(II) as probe species undergoing reversible electrochemical processes. These devices were then used for the single electrode detection of ascorbic acid in aqueous samples and the dual electrode detection of orthodiphenols in extra virgin olive oils (EVOOs). In fact, these devices enable hydrophilic orthodiphenols, typically present in EVOOs (extracted by a 80:20% v/v acetonitrile/water mixture), to be discriminated from hydrophilic monophenols instead present in almost all vegetable oils. Flow-injections runs were conducted by using a 0.01 M H2SO4 + 0.5 KCl running electrolyte allowing the rapid and selective detection of hydrophilic orthodiphenols with satisfactory sensitivity and a low enough detection limit (2 μM). Different real samples of EVOOs and sunflower oils were analyzed. Abundant enough contents of orthidiphenols were found in EVOO samples, while no trace of these antioxidants was found in sunflower oils.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antioxidants; Cotton thread electroanalytical devices; Extra virgin olive oil; Orthodiphenols; Paper based dual electrochemical detectors; Pencil-drawn electrodes

Mesh:

Substances:

Year:  2018        PMID: 30327115     DOI: 10.1016/j.aca.2018.06.061

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Simple, fast, and instrumentless fabrication of paper analytical devices by novel contact stamping method based on acrylic varnish and 3D printing.

Authors:  Tatiane Alfonso de Araujo; Natália Canhete de Moraes; Jacqueline Marques Petroni; Valdir Souza Ferreira; Bruno Gabriel Lucca
Journal:  Mikrochim Acta       Date:  2021-11-27       Impact factor: 5.833

Review 2.  Recent advances in thread-based microfluidics for diagnostic applications.

Authors:  Xuan Weng; Yuejun Kang; Qian Guo; Bei Peng; Hai Jiang
Journal:  Biosens Bioelectron       Date:  2019-03-08       Impact factor: 10.618

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.