Literature DB >> 30327111

Hollow-fiber renewal liquid membrane extraction coupled with 96-well plate system as innovative high-throughput configuration for the determination of endocrine disrupting compounds by high-performance liquid chromatography-fluorescence and diode array detection.

Daniela Lopes1, Adriana Neves Dias2, Josias Merib3, Eduardo Carasek4.   

Abstract

This paper describes a new configuration of the hollow fiber renewal liquid membrane (HFRLM) procedure for the high-throughput determination of the endocrine disrupting compounds 4-nonylphenol, 4-octylphenol, 4-tert-octylphenol, methylparaben, ethylparaben and bisphenol A using a 96-well plate system and high-performance liquid chromatography. In this configuration, cylindrical blades were adapted as a support for polypropylene membranes used as supported liquid membranes in the HFRLM approach. The proposed configuration exhibited important advantages including high-throughput, low solvent and sample consumption, and good analytical performance. The optimized extraction conditions were achieved with the use of a mixture comprised of 50:50 v/v 1-octanol:hexane as the supported liquid membrane, sample pH 5, extraction solvent 15 μL (hexane) and extraction time 45 min. The limits of quantification varied from 0.5 μg L-1 for 4-octylphenol to 15 μg L-1 for methylparaben and ethylparaben and the r2 ranged from 0.9908 for methylparaben to 0.9992 for 4-tert-octylphenol. HFRLM combined with the use of a 96-well plate provides an environmentally-friendly configuration. It offers good accuracy when applied to analyze water samples, with relative recoveries ranging from 72 to 130%, for 4-octylphenol and 4-nonylphenol, respectively, and precision varying from 1 to 14.3%, for 4-nonylphenol at 1.0 μg L-1 and bisphenol A at 8.0 μg L-1, respectively.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  96-Well plate; Endocrine disrupting compounds; HFRLM; High-throughput; Water samples

Year:  2018        PMID: 30327111     DOI: 10.1016/j.aca.2018.07.032

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  1 in total

1.  Hollow fiber liquid-phase microextraction combined with supercritical fluid chromatography coupled to mass spectrometry for multiclass emerging contaminant quantification in water samples.

Authors:  Vilma Del Carmen Salvatierra-Stamp; Silvia G Ceballos-Magaña; Norma Susana Pano-Farias; José Belisario Leyva-Morales; Kayim Pineda-Urbina; Roberto Muñiz-Valencia
Journal:  Anal Bioanal Chem       Date:  2021-02-03       Impact factor: 4.142

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.