To solve the thrombosis and restenosis problem in cardiovascular stent implantation for cardiovascular artery disease, chondroitin 6-sulfate (ChS) with heparin (HEP) have been used as drug carrier layers and alternatively covalently bonded on gold (Au)-dimercaptosuccinic acid (DMSA)-thiolized cardiovascular metallic (SUS316 L stainless steel, SS) stents. Sirolimus, a model drug, was encapsulated in the ChS-HEP alternative layers. The behavior of the drug in releasing and suppressing the growth of smooth-muscle cells (SMCs) was evaluated with 5-layer CHS-HEP coating on the SS stents. Moreover, hemocompatibility of blood clotting time and platelet adhesion was performed. The results showed that the 5-layer ChS-HEP-modified SS stents displayed the greatest hemocompatibility, showing prolonged blood clotting time of the activated partial thrombin time (> 500 s) and less platelet adhesion to reduce thrombosis. Furthermore, sirolimus can be released continuously for more than 40 days with the 5-layer ChS-HEP coating and is beneficial for inhibiting the growth of SMCs; however, it does not affect the proliferation of endothelial cells, which can avoid restenosis formation. Therefore, the multilayers of ChS-HEP grafted onto the Au-DMSA-cardiovascular SS stents provide high potential for use as drug eluting stents.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiovascular metallic stents; Chondroitin 6-sulfate; Hemocompatibility; Heparin; Restenosis; Thrombosis

Mesh:

Substances:

Year:  2018        PMID: 30326363     DOI: 10.1016/j.colsurfb.2018.10.014

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  3 in total

1.  Anti-Thrombogenicity Study of a Covalently-Attached Monolayer on Stent-Grade Stainless Steel.

Authors:  Tairan Yang; Brian De La Franier; Michael Thompson
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

Review 2.  Anti-thrombogenic coatings for devices in neurointerventional surgery: Case report and review of the literature.

Authors:  Hans Henkes; Pervinder Bhogal; Marta Aguilar Pérez; Tim Lenz-Habijan; Catrin Bannewitz; Marcus Peters; Christina Sengstock; Oliver Ganslandt; Pedro Lylyk; Hermann Monstadt
Journal:  Interv Neuroradiol       Date:  2019-06-27       Impact factor: 1.610

3.  Bioresorbable vascular stents and drug-eluting stents in treatment of coronary heart disease: a meta-analysis.

Authors:  Le Ni; Hao Chen; Zhurong Luo; Yunqiang Yu
Journal:  J Cardiothorac Surg       Date:  2020-01-28       Impact factor: 1.637